Technical specifications
Crocus CNV
152
Reference manual
12.3 Management interface
The possible management interfaces are:
Management interface
Connector
Speed
asynchronous through the auxiliary
connector
9 pins subD
(on the Crocus CNV)
9600 bps, 8+N
synchronous through the Orchid 1003 LAN
RJ45
(on the CN4 card nest)
800 kbps
12.4 Auxiliary connector
The auxiliary connector (sometimes also called control port) is a 9 pins subD connector that is labelled
CTRL. The signals on these connector are V.24 / V.28 signals.
The auxiliary connector layout
The auxiliary connector has the following pin layout:
Pin Signal
DCE
Figure
1 not
used
-
2 NMS
RxD
output
3 NMS
TxD
input
4 not
used
-
5 GND
-
6 not
used
-
7 NMS
RTS
input
8 NMS
CTS
output
9 not
used
-
Remarks
•
The connection with TMA can be made with a straight 9 pins subD (Male/Female) cable or a regular
25/9 pins subD adapter cable.
•
For a Table Top, the cable to connect the TT with the Orchid 1003 LAN management concentrator
can be ordered at the distributor (code 149220).
•
For a Card Version, the connection to the Orchid 1003 LAN management concentrator is made
through the high speed bus of the CN4 card nest. Refer to the CN4 manual for more information.
1
2
3
4
5
6
7
8
9
Содержание Crocus CNV
Страница 1: ...Crocus CNV Crocus CNV USER and REFERENCE MANUAL Version 1 5 500866...
Страница 10: ......
Страница 11: ...Crocus CNV User manual 1 User manual...
Страница 12: ...Crocus CNV 2 User manual...
Страница 84: ...Crocus CNV 74 Reference manual Reference manual...
Страница 85: ...Crocus CNV Reference manual 75...
Страница 136: ...Alarm attributes Crocus CNV 126 Reference manual...
Страница 165: ...Crocus CNV Annexes 155 Annexes...
Страница 166: ...Crocus CNV 156 Annexes...
Страница 168: ...Annex A product information Crocus CNV 158 Annexes...