ExpressBox 16 Smart | 55
5
Express I/O Manager
ExpressBox 16 Smart contains extra features that could be utilized to monitor the status of the components on the backplane and the items in
the chassis such as the state of the power supplies, fan status, and temperature. It is observed on a remote computer that would indicate when
an equipment malfunction has occurred. This product can be divided into multiple individual groups of I/O supporting 4 independent host
computers through partitioning and purchasing additional host/expansion link cards and cables.
5.1
Web Server and SNMP Features
ExpressBox 16 Smart supports the Simple Network Management Protocol (SNMP) for remote monitoring and administration by offering the
following features:
Internal Temperature monitoring
Clear Alarm button monitoring
Swappable fan status (for fans 1,2,3 and 4 in the front)
Power supply 1 status
Power supply 2 status
Traps are defined to alert the SNMP server in case of overheat or failure in any of the subsystems mentioned above
Remote chassis turn on
Input/ Output switching
Partitioning of PCIe slots for additional users
5.2
Web Access and SNMP Configuration
To ensure that you can successfully monitor your new system, you will need to connect it to a local or private hub using a standard RJ-45
Ethernet Cable. Connect one end of the cable to the RJ-45 port, located to the right of the power supply modules (back of the chassis), and the
other end to your local area network connector or any computer. In case you connect the chassis to a local computer/laptop, be sure to use a
Hub with a regular network cable
or
a crossover cable without a Hub.
To obtain access to the OSS chassis, direct your web browser to the given IP address:
192.168.1.10
.
You must configure your network on this same domain for this to work. Later, you can change the IP address to another domain or to use
DHCP.
Configure your computer’s network setting to correlate to the default IP address of the OSS chassis . The IP address of the OSS chassis is
192.168.1.10
and the Subnet Mask is
255.255.255.0
.
Set your network settings to configure manually and enter an IP address for your computer of 192.168.1.42 where 42 can really be any free
number other than 10.
To verify the OSS Expansion chassis unit is detected on the network, open your web browser and direct it to the IP address of the chassis that is
192.168.1.10
. The window for the browser will appear as shown:
Содержание EB16-SX8
Страница 12: ...One Stop Systems ExpressBox 16 Smart 12 1 6 Basic Main Components...
Страница 14: ...One Stop Systems ExpressBox 16 Smart 14...
Страница 38: ...One Stop Systems ExpressBox 16 Smart 38 4 4 Backplane This is current new EB16 backplane...
Страница 42: ...One Stop Systems ExpressBox 16 Smart 42...
Страница 45: ...One Stop Systems ExpressBox 16 Smart 45...
Страница 67: ...One Stop Systems ExpressBox 16 Smart 67 5 13 3 PCI E Info for Configuration 3...
Страница 80: ...One Stop Systems ExpressBox 16 Smart 80 Manual P N 09 09979 00 Rev C...