background image

 

STAND: 17.06.2019 

9910_Operation_Manual_STANDCONTROL_C1_Rev1v1_EN 

Seite 23 von 41 

9.4  Safety-Stop / Safety zone 

The safety stop is an additional stop above the minimal position. At this position, the table stops auto-
matically when the  -button is pressed. To further reduce the table height, first release the button and 
then press it again. 
Below the safety-stop, the controller moves with reduced speed until it reaches the minimal position. 
The safety stop is unchangeably stored in the controller. 

 

Note:

 No positions can be saved below the safety stop. The table moves with  

reduced speed downward only. 

Содержание STAND.CONTROL C1

Страница 1: ...STAND CONTROL C1 Table Controller Valid from Firmware Version A1 2...

Страница 2: ...as optional accessories 12 6 1 Delivery scope 12 6 2 Necessary accessories 12 6 3 Optional accessories 12 7 Installation 14 7 1 Unpacking 14 7 2 Installation 14 7 2 1 Assembly with tools 14 7 2 2 Ass...

Страница 3: ...configuration 27 10 1 8 Delete shelf and container stop depending on the configuration 28 10 1 9 Automatic movement 28 10 2 Collision detection STAND GUARD G1 29 10 3 Cascading 30 11 Disassembly Main...

Страница 4: ...est and quality inspection before they leave our factory Should you nonetheless have prob lems with your table controller you can contact our service department at any time It is essential that the ta...

Страница 5: ...iations Abb Term Meaning OMT Oelschl ger Metalltechnik GmbH Controller Table controller STAND CONTROL C1 Reset position Lowermost mechanical end position of the table Minimal position Lowermost softwa...

Страница 6: ...group These operating instructions are aimed at the following group of persons The commissioning staff who assembles and commissions the sit stand desks Furniture installers maintenance staff who comm...

Страница 7: ...e respective section of the operating instructions 3 4 1 General safety instructions Note Please read and take note of without fail the operating manual before assembly commissioning of the table cont...

Страница 8: ...Warning If there is a malfunction for example unwanted movement of the table top if for example a button of the hand switch gets stuck please immediately unplug the power cord Danger Protect all elec...

Страница 9: ...must read these operating instructions before you start using the product Point out to your consumer that the operating instructions must be kept near the product Danger It is mandatory that you put y...

Страница 10: ...tion that the controller is assembled and used in an appropriate and technically correct manner within the framework of the parameters described maintenance is carried out correctly and repairs are on...

Страница 11: ...e 1 Depiction of the controller and its connections 1 Surface for type rating plate 2 Surface for company logo 3 RJ45 socket D1 for hand switch cascading or other accessories 4 RJ45 socket D2 for hand...

Страница 12: ...itting on the desktop see Section 7 2 1 and Basically this operating manual assumes a two motor table with a connected simple hand switch of the STAND MOVE M1 0 model All the descriptions can be carri...

Страница 13: ...41 RJ45 multi plugs for expanding the number of device connections STAND CONNECT hub connecting cables STAND CONNECT connecting cables PC software CON STAND only for service engineers LIVE STAND USB...

Страница 14: ...ally fitted with screws below the desktop Alternatively it is possible to install the controller with a controller holder if the table top support frame is already pre fitted for it for example FREE S...

Страница 15: ...oller to be fitted For fitting controllers using controller brackets follow the procedure below 1 Fit the two controller brackets as shown below in the keyhole in the chassis beams Turn them 90 in a c...

Страница 16: ...r assembly with these controller brackets Pencil Drilling machine 2 screws Screwdrivers of a size suitable for the screws Note The screws are not included in the scope of delivery since they have to b...

Страница 17: ...on the table controller at the desired place Ensure that the leg space of the user is not constrained 2 Mark the bore holes with a pencil 3 Drill the marked places for the screws with the drilling mac...

Страница 18: ...an integrated motor cable In this case you can skip to the next step Connect the free end of the motor cable of the left hand column with one of the motor terminals M1 or M2 Connect the free end of t...

Страница 19: ...ains supply before every enhancement or replacement of accessories 8 3 Connecting the mains cable Danger Ensure that the mains voltage and frequency prevalent in your country are the same as the data...

Страница 20: ...nd the controller the controller of the table has to be initialised If the controller is expecting an initialisation the table can only move downward For this purpose press the key Press the key until...

Страница 21: ...Only trained personnel should carry out setting and deletion of container and shelf stops There is a danger of injury from wrong setting or removal of the Stop positions and a danger of the table gett...

Страница 22: ...tainer stop or safety stop that is present is ignored First remove all hindrances below the table for example Rollcontainer and pay heed to the increased risk of injury 9 3 Collision detection Warning...

Страница 23: ...able stops auto matically when the button is pressed To further reduce the table height first release the button and then press it again Below the safety stop the controller moves with reduced speed u...

Страница 24: ...hown in the display If the hand switch is not operated for a prolonged period the display goes off provided there is no error being shown currently Pressing any button switches the display on again Wi...

Страница 25: ...tch and can navigate through it with the arrow keys and Structure of the menu Change the height display inches cm Section 10 1 4 Adjust the height display Section 10 1 5 Factory reset Section 10 1 6 S...

Страница 26: ...o to the menu of the hand switch 3 If necessary navigate with the arrow keys and to menu option 2 The display must show 4 Confirm the selection by once again pressing the Logo key The height of the mi...

Страница 27: ...ional stops the safety of the table system can be increased in that the possible movement path is restricted Container and shelf stops are safety positions that cannot be run over during normal operat...

Страница 28: ...the shelf stop upper stop b Press to delete the container stop lower stop 5 Confirm the input by once again pressing the Logo key Alternatively wait for approx 6 seconds 6 You are once again in the ma...

Страница 29: ...upply This is the case for example when the sensor is newly connected to an active controller or a configured system including the sensor is connected to the mains supply For the calibration the senso...

Страница 30: ...cading the controllers proceed as follows 1 Connect the controllers with a STAND CONNECT connecting cable 2 Connect additional accessories as provided in Section 8 2 to the free RJ45 slots of the cont...

Страница 31: ...supply Danger If you find defective cables immediately isolate the controller from the mains Pull the mains plug Check the plug and connector joints at the controller regularly for firm fitting Check...

Страница 32: ...r contact customer service Carry out an initialisation movement Communications error Hold the button pressed down for at least 10 seconds to force a re configuration of the system Table is not moving...

Страница 33: ...STAND 17 06 2019 9910_Operation_Manual_STANDCONTROL_C1_Rev1v1_EN Seite 33 von 41 Fault description Troubleshooting Check the loading of the table Reduce the weight on the table...

Страница 34: ...ted Reset Initialisation movement has ended key continues to be pressed Release the key 2 Set container or shelf stop Confirmation The position was successfully saved 3 First movement after sensor out...

Страница 35: ...e or connect the correct motor to the relevant socket Start the controller again If required carry out a reference movement Overcurrent at motor 1 Max load exceeded remove the load from the table If r...

Страница 36: ...erence movement required or Initialisation movement is carried out Carry out a reference movement System protection system pause The powering on duration of the sys tem was exceeded Wait until the con...

Страница 37: ...50 weight 0 54 kg Environmental conditions during transport and storage 25 C to 70 C at 5 to 90 relative atmos pheric humidity non condensing with 38 C max dew point Temperatures from 55 C to 70 C on...

Страница 38: ...STAND 17 06 2019 9910_Operation_Manual_STANDCONTROL_C1_Rev1v1_EN Seite 38 von 41...

Страница 39: ...6 3 2007 A1 Electromagnetic Compatibility EMC EN 61000 3 2 2014 Electromagnetic Compatibility EMC EN 61000 3 3 2013 Electromagnetic Compatibility EMC Electrical safety low voltage directive 2014 35 E...

Страница 40: ...in accordance with the applicable WEEE directive 2012 19 EU Figure 9 Identification markings for products in accordance with WEEE Directive 2012 19 EU Dispose of the product and all other materials a...

Страница 41: ...ges to the text and graphics to match them to the purpose of the end user documentation The texts and graphics may not by published or sub licensed either unchanged or modified through the digital rou...

Отзывы: