64
ZEN Image Display
Section 5-2
With LCD-type CPU Units, operation buttons can be used by the
simulator. Either momentary or alternate operation can be selected
by right-clicking the operation button symbols.
Operation Button Symbols
• External inputs can be turned ON and OFF by clicking the input
symbols. When an external input is turned ON, the color of the
connection line between the input symbol and the ZEN terminal
changes to green.
• The results of ladder program processing can be checked by
observing the status of lamp symbols connected to output
terminals (RUN mode only).
Lamp Symbols
• When a display bit (D) is used in the ladder program, the display
conditions are shown on the ZEN display (RUN mode only).
Alternate: NO
condition
Remains ON after being clicked.
Remains OFF after being clicked again.
Alternate: NC
condition
Remains OFF after being clicked.
Remains ON after being clicked again.
Analog input
Select when using I4/I5 as analog inputs
with a DC-type CPU Unit.
Symbol
Input
specifications
Operation
Input specifications
Operation
Momentary
Normally OFF.
ON only when left mouse button is held down.
Alternate
Remains ON after being clicked.
Remains OFF after being clicked again.
Symbol
Status
Output terminal OFF
Output terminal ON
Z184-E1-04.book Page 64 Thursday, November 20, 2008 4:25 PM