43 of 135
(2) Reader status output
Data is output depending on the reader status.
Available conditions
Function
Output timing
Note
RUN
Running Normally
Same action as RUN LED (except for blink).
ERR
Abnormally stopped
Same action as ERR LED (except for blink).
COM
Communication status
Same action as OR of AT1-4 LED.
ATn (n:1 to 4)
Antenna ”n” is specified.
Same action as LED of AT1, AT2, AT3, and AT4.
(3) Communication result judgment
Upon the response for communication process is returned, the reader sends judgment signal depending
on the specified conditions to the corresponding Digital output port (1-4). This function provides two
judgment and output time for each output port.
Available conditions
Function
Output timing
Condition setting
Option
NORMAL
The process is
finished normally.
-The read/written tag count:
Operator (>=, <=, ==, !=)
Compared number
-Data comparison:
Operator (==, !=)
Compared data
Output duration
ERROR
The process is
finished abnormally.
Error code
Output duration
2.3.4 Firmware Update
You can update the firmware by specifying update files via Web browser. Updated data shall be effective upon
subsequent power-ups.