3.2 Examples
Examples given in this section are provided as a guide for the user in determining command suitability. They
do not constitute a warranty. You should verify operation in their specific environment and application.
3.2.1 Example 1
To read a tag attached on the same face to each case that rushes on conveyor in high speed, Single Repeat
sequence is appropriate. An example command is the following:
Command: RDID –seq SRP –ant 1 –tmo 200
3.2.2 Example 2
To read a tag attached on various faces (top face is the most) to each case that passes through a gate on a
conveyor, the client software finds tags using 3 antennas (making much of antenna 2). An example is the
following:
Command: RDID –seq SRP –ant 212232 –tmo 1000
antenna 1
cases
conveyor
antenna 2
antenna 1
tag
antenna 3