43
V530-R2000
User’s Manual
SECTION 5
Se
tt
in
g
the
T
rigge
r M
ode
SECTION 5
System Settings
Setting the Trigger Mode
Both the mode for the read trigger input from the TRIG input terminal and the Read Mode can
be set.
l
System Set./Trigger Mode
1.
Make the settings for each item.
2.
Select
OK
.
The Trigger Mode Setting is valid only for the TRIG input terminal.
The trigger from the Console is always a one-shot trigger.
Item
Selections
Description
Trigger Mode
One Shot
(default)
One reading is performed synchronized on the rising edge (OFF to
ON transition) of the trigger signal. If reading is successful, reading
is ended and the reading results is output.
The trigger signal is also synchronized as the camera shutter input
to enable taking images of moving workpieces in an accurate posi-
tion.
Continuous
Reading is perform continuously as long as the trigger signal is ON.
Level
Reading is repeated until successful while the trigger signal is ON.
If reading is not performed successfully,
NG
is output when the trig-
ger signal turns OFF.
Read Timeout
1 to 99
(default: 99)
Set the timeout period.
The timeout period is the period from input of the trigger until read-
ing is forced to end.
Trigger Mode
Cancel
OK
Trigger Mode
Read Timeout
Read Mode
: One Shot
: [
99
]sec
:Normal
Содержание V530-R2000
Страница 1: ...USER MANUAL Cat No Q134 E1 1A V530 R2000 2D Code Reader Fixed...
Страница 33: ...16 V530 R2000 User s Manual SECTION 2 MEMO...
Страница 55: ...38 V530 R2000 User s Manual SECTION 4 MEMO...
Страница 63: ...46 V530 R2000 User s Manual SECTION 5 MEMO...
Страница 111: ...94 V530 R2000 User s Manual SECTION 7 MEMO...