55
V500-R521B2/C2
User’s Manual
Se
ct
io
n
4
How to
Use Menu
Sheet/Command
Section 4
Setting Method
Transmission method of the command by designating values and characters is
explained as follows.
E.g. 1: Set "AB [CR]" on header. (When designating codes directly)
E.g. 2: Set "AB [CR]" on header. (When designating hexadecimal number directly)
E.g. 3: Reading number of digit is set to "8-digit" and "12-digit".
"00H" (zero) cannot be designated as header or footer. It is regarded as end character.
Characters until just before 00H are valid.
Transmit a header setting command.
Transmit a character "A".
Transmit a character "B".
Transmit CR code.
Transmit a header setting command.
Transmit 41 "A" in hexadecimal number.
Transmit 42 "B" in hexadecimal number.
Transmit CR code.
Transmit the number of digit command "A".
Transmit "8-digit". (Input in decimal number.
Numbers are fix to 2-digit.)
Transmit the number of digit command "B".
Transmit "12-digit". (Input in decimal number.
Numbers are fix to 2-digit.)
V500-R521.book 55 ページ 2008年7月18日 金曜日 午後1時1分