107
V500-R521B2/C2
User’s Manual
Sec
tion
5
How to Use Command
L
in
k
Un
it
V7
00-
L1
2
Section 5
Example of System Configuration
Buffer clear (C)
Clears all the buffer in the link unit.
Input command
Response
When a code other than 00 is returned p.110
Change the communication frame with the bar code reader to [CR] (X)
Input command
Response
When a code other than 00 is returned p.110
Communication frame with the bar code is as shown below.
Change the communication frame with the bar code reader to
[STX] to [ETX] (Y)
Input command
Response
When a code other than 00 is returned p.110
Communication frame with the bar code is as shown below.
However, it returns to default ([CR] mode) when the power is turned on or off.
$01
$10
C
$0D
(Check code)
(Machine No.)
$01
0
0
$0D
(Check code)
(Machine No.)
$01
$10
X
$0D
(Check code)
(Machine No.)
$01
0
0
$0D
(Check code)
(Machine No.)
Communication data with the bar code reader
CR
$0D
Control code indicating frame end
$01
$10
Y
$0D
(Check code)
(Machine No.)
$01
0
0
$0D
(Check code)
(Machine No.)
Communication data with the bar code reader
$02
SOH
CR
Control code indicating frame end
Control code indicating frame start
$03
V500-R521.book 107 ページ 2008年7月18日 金曜日 午後1時1分