Section 3
Function Explanation
Test Reading Function
You can check how stably the subject bar code can be read.
Read a bar code at resting state for one sec. and calculate the reading rate.
To enter reading measurement mode using a command
1.
Install the bar code at a reading position.
2.
Enter command "7U".
Mode enters to reading rate measurement mode.
Reading rate of every one sec. is measured.
3.
To finish the reading rate measurement mode, enter reset command "Z1" or re-start the
bar code reader.
Return to the normal measurement mode.
To enter reading measurement mode using a TEST button on the
back side
1.
Install the bar code at a reading position.
2.
Keep pressing the TEST button until the buzzer (tones repeating "Sol" and "Do")
sounds.
3.
Press the TEST button once.
Mode entered to reading rate measurement mode.
(Reading rate of every one sec. is measured according to the reading condition of factory default.)
4.
To finish the reading rate measurement mode, enter reset command "Z1" or re-start the
bar code reader.
Return to the normal measurement mode.
Do not execute write command "Z2" to nonvolatile memory.
A sample setting condition is overwritten and stored, which erases the already set reading condition.
Press the TEST button within 10 sec. after the buzzer sounds.
After 10 sec. or more have passed, it returns to the original state.