90
Sec
tion
5
Ex
ample of
Con
n
ec
tion wit
h
Pr
ogra
m
ma
ble Co
ntr
o
lle
r (CS1)
V500-R521B2/C2
User’s Manual
Section 5
Example of System Configuration
Setting at bar code side
Set as follows, using UB command (collective setting for programmable controller
connection).
p.59
Setting of CS1 side
For detail setting method, refer to the operation manual of your programmable controller.
Setting item
Setting content
Command
Communication speed
9600 bps
(Same as initial setting)
Data length
7-bit
L0
Parity
Even number
L3
Stop bit
2-bit
L6
Header
None
(Same as initial setting)
Footer
CR
(Same as initial setting)
Reading valid time
T 2 sec.
Y2
Process when reading failed
?[CR] or > [CR] is transferred
5H
Setting item
Setting content
Dip switch of CPU unit
OFF
PC system setting
160[8300]
161[0000]
164[000D]
165[0100]
DM setting
Set [1B5A] to DM00100.
(Memorize "Z" of ASCII code)
V500-R521.book 90 ページ 2008年7月18日 金曜日 午後1時1分