Section 4
Setting Method
Setting related to READ OK/NG signal output
(Only when V500-R521B2 is used)
When you want to output reading succeeded/failed to READ OK/NG signal, set the
conditions of output system and duration, then execute "signal output (8Q)".
Output system p.28
Menu sheet
Command
Menu sheet
Command
Signal output
(Factory default setting)
8Q
Signal output one-shot duration; 30 ms 8I
No signal output
8R
Signal output one-shot duration; 40 ms 8J
Signal output trigger signal
synchronous system (positive logic)
(Factory default setting)
8C
Signal output one-shot duration; 50 ms 8K
Signal output trigger signal
synchronous system (negative logic)
8D
Signal output one-shot duration; 60 ms 8L
Signal output one-shot system
(positive logic)
8E
Signal output one-shot duration; 70 ms 8M
Signal output one-shot system
(negative logic)
8F
Signal output one-shot duration; 80 ms 8N
Signal output one-shot duration; 10 ms 8G
Signal output one-shot duration; 90 ms 8O