manualshive.com logo in svg
background image

 

 

Z253-E1-02

Cat. No.

Bar Code Reader

User’s Manual

V500-R521B2/C2

Authorized Distributor:

In the interest of product improvement, 
specifications are subject to change without notice.

Cat. No. Z153-E1-02

OMRON Industrial Automation Global: 

www.ia.omron.com

Printed in Japan

0708-0.5C (0307) (M)

OMRON Corporation

Industrial Automation Company

Regional Headquarters

OMRON EUROPE B.V.
Sensor Business Unit

Carl-Benz-Str. 4, D-71154 Nufringen,
Germany
Tel: (49) 7032-811-0/Fax: (49) 7032-811-199

OMRON ELECTRONICS LLC

One Commerce Drive Schaumburg,
IL 60173-5302 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787

OMRON ASIA PACIFIC PTE. LTD.

No. 438A Alexandra Road # 05-05/08 (Lobby 2), 
Alexandra Technopark, Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711

OMRON (CHINA) CO., LTD.

Room 2211, Bank of China Tower, 
200 Yin Cheng Zhong Road, 
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200

Sensing Devices Division H.Q.
Application Sensors Division

Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81) 75-344-7068/Fax: (81) 75-344-7107

 © OMRON Corporation 2007  All Rights Reserved.

Cat. No. Z253-E1-02

Bar Code Reader V500-R521B2/C2

User’s Manual

Содержание V500-R521B2

Страница 1: ...Bar Code Reader User s Manual V500 R521B2 C2 Cat No Z253 E1 02 Bar Code Reader V500 R521B2 C2 User s Manual...

Страница 2: ...performance and application methods of the V500 R521B2 C2 This manual is intended for personnel with knowledge of electrical systems Be sure to read and understand this manual thoroughly before using...

Страница 3: ...dix Introduction Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 READ AND UNDERSTAND THIS DOCUMENT Be sure to read this Product Overview Wiring and Installation Function Explanation Settin...

Страница 4: ...REGARDING THE PRODUCTS UNLESS OMRON S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED STORED INSTALLED AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION ABUSE MISUSE OR INAPPROPRIATE MODIFICA...

Страница 5: ...improvements and other reasons It is our practice to change model numbers when published ratings or features are changed or when significant construction changes are made However some specifications o...

Страница 6: ...which if not avoided will result in minor or moderate injury or may result in serious injury or death Additionally there may be significant property damage Indicates a potentially hazardous situation...

Страница 7: ...plied with this product Usage Use laser enclosure device to prevent specular object from reflecting laser beam When used without an enclosure be sure to avoid a laser path from eye level Although the...

Страница 8: ...easures against high voltage spikes safe extra low voltage circuits on the secondary side p 30 Other Precautions If the product becomes extremely hot or abnormal odors or smoke occurs stop using the p...

Страница 9: ...water oil or chemical agent 2 Power supply Apply voltage to be 5 VDC 10 at the connector of the bar code reader side Used cable should be 0 3 mm2 or equivalent within 5 m When the wiring is too long o...

Страница 10: ...Use the associated screw to mount the insulation board Incline the bar code reader about 15 to read the target bar code Do not apply stress on the cable when mounting and using Distance and angle all...

Страница 11: ...racter or more and 2 5 mm or more is necessary of both right and left side of the label Rough standard 12 or 13 times or more of the narrow bar width 9 To improve reading reliability When the digit is...

Страница 12: ...g Files Using the 2DCR Configear Creates the data setting file for loading set data to the Handheld 2D Code Reader Make the settings for the communications conditions functions and display conversion...

Страница 13: ...Introduction Visual Aids Indicates points that are important in using product functions or in application procedures Indicates page numbers providing related information Indicates helpful information...

Страница 14: ...se 6 Precautions for Correct Use 7 How to Use This Manual 10 Visual Aids 11 Section 1 Product Overview 15 Features 16 Product Composition 18 Part Names 19 Rating Performance 20 Usage Flow Chart 24 Sec...

Страница 15: ...ample of System Configuration 87 Example of Connection with a PC 88 Example of Connection with Programmable Controller CS1 89 Example of Multi drop Connection 92 How to Use Command Link Unit V700 L12...

Страница 16: ...V500 R521B2 C2 User s Manual Section 1 Product Overview This section explains about features and rating performance of this bar code reader Features 16 Product Composition 18 Part Names 19 Rating Perf...

Страница 17: ...t installation work and maintenance work hour can be greatly reduced p 49 Simple function setting You can either set the function by reading a menu sheet or by inputting a command on the upper equipme...

Страница 18: ...iability and wide reading distance of 60 mm to 270 mm in case of narrow bar width 1 0 mm p 21 Easy multi drop Connect communication link unit V700 L12 to collect read data from plural bar code readers...

Страница 19: ...s Select according to connecting upper equipment V500 R521B2 Cable output type Tip of the cable is loose end V500 R521C2 Connecter output type Tip of the cable is a connector Use an appropriate connec...

Страница 20: ...Part Names Front side Back side Reading window Laser beam radiates from here Main cable 2 m Laser alarm label bottom side READ NG LED Illuminates when not read correctly TEST button Press it once to r...

Страница 21: ...times Reading check Buzzer sound indication LED Interface Communication specification RS 232C OK NG output Only V500 R521B2 NPN open collector output 24 VDC 30 mA Function set method Menu sheet readi...

Страница 22: ...ntrast MRD 63 PCS 0 9 Bar code CODE39 Installation condition Pitch angle 0 skew angle 15 Tilt angle 0 curvature R 1 Distance from the end of the case 2 Value at a reading angle 30 Narrow bar width Rea...

Страница 23: ...gits MRD 63 PCS 0 9 Reading distance 100 mm from the case end Installation condition Skew angle 15 tilt angle 0 curvature R Skew angle In the following conditions readable up to 50 However range from...

Страница 24: ...he bar code height Scan all the bar code with the laser Curvature In case of the following conditions the bar code of 8 digit EAN curvature range 15 mm or more and 13 digit EAN curvature range 20 mm o...

Страница 25: ...he type width height and numbers of digit of bar codes p 20 Rating Performance p 127 Corresponding Bar Code List Wiring p 28 Wiring Connect peripheral equipment p 87 Example of System Configuration Ch...

Страница 26: ...ge environment p 49 Test Reading Function Execute reading Read only the registered bar code p 83 Setting related to sorting read In case of trouble A bar code cannot be read correctly p 120 Troublesho...

Страница 27: ...Wiring and Installation 27 V500 R521B2 C2 User s Manual Section 2 Wiring and Installation This section explains about the wiring method and installation method of the bar code reader Wiring 28 Instal...

Страница 28: ...reverse connection of power supply or connection to alternating current Do not use exceeding rating voltage Turn off the power switch before connecting or disconnecting a connector Use a wrist strap...

Страница 29: ...l synchronous system Maintains ON condition until the next trigger is input You can select positive logic negative logic One shot system READ OK NG signal is turned on during the preset time one shot...

Страница 30: ...RS Transmission request 4 CS Transmission allowed 5 TRIG External trigger signal 6 NC Not connected 7 S GND 0 V External 8 VCC Power supply External Usage Manufacturer Model For cable relay Hosiden Co...

Страница 31: ...traight cable Diameter 3 8 0 5 mm Length 2000 50 mm Number of core 9 Item Minimum value Maximum value Terminal voltage Von when a transistor is turned on 0 V 1 3 V Terminal voltage Voff when a transis...

Страница 32: ...on the bar code reader 2 Install When inductive noise is generated at the mounting bracket attach an associated insulation board Use the associated screw to install the insulation board Do not apply s...

Страница 33: ...Material SUS304 Insulation board accessory Material Fabric bake When the associated mounting bracket and insulation board are not used install it by referring to the outline dimension figure p 114 Sma...

Страница 34: ...521B2 C2 User s Manual Section 3 Function Explanation This section explains about representative functions of the bar code reader Explanation of Reading System 36 Operation Flow Chart 38 Communication...

Страница 35: ...he external trigger signal is turned on laser radiates and starts reading The Trigger controlled system reads during the trigger is ON and the Effective duration designation system reads only the effe...

Страница 36: ...G signal output differs according to the reading operation setting READ OK NG signal output is only for V500 R521B1 In case of single reading and plural reading When reading succeeded OK signal is out...

Страница 37: ...se 2 In case of trigger controlled system reads while the trigger is ON consider that the reading effective duration is set to 0 Power on Wait for the reading trigger Laser radiation Reading process e...

Страница 38: ...effective duration is set to 0 Power on Wait for the eading trigger Laser radiation Reading process execution Is reading succeeded Repeat Is reading trigger end 1 Has reading effective duration passed...

Страница 39: ...onsider that the reading effective duration is set to 0 Power on Wait for the reading trigger Laser radiation Reading process execution Is reading succeeded Repeat Is reading trigger end 1 Has reading...

Страница 40: ...r code reader waits for the upper equipment response after transmitting the data When ACK 06H 1 byte is received from the upper equipment buzzer sounds indicating the normal finishing and ends data tr...

Страница 41: ...ing to communication condition In case of continuous reading and plural reading laser is always radiating during trigger input is ON or during reading effective duration Concept of T0 to T4 other than...

Страница 42: ...imum OFF time Be sure to set 30 ms or more T4 Communication time Differs according to communication condition In case of continuous reading and plural reading laser is always radiating during trigger...

Страница 43: ...condition Operation Flow Chart p 38 Confirmation of trigger input timing When constructing the system to read the moving bar code input timing of the external trigger signal is important Input the ext...

Страница 44: ...tion against the scanning direction As the appropriate direction differs according to the size of a label investigate when installing Bar code moving direction Scanning range Whole height of a bar cod...

Страница 45: ...der and the upper equipment Reading trigger input by RS 232C command Reading trigger command format is as shown below Set command input Reading condition set command can be transmitted from the upper...

Страница 46: ...rings to add at the head of transmitted data Max 4 arbitrary characters can be set No header Number of digit Number of digit of the read data is output in two digit ASCII code Whether or not to output...

Страница 47: ...with C D to adjust the number of digit to be in accordance with EAN 13 0 S X1 X2 X3 X4 X5 X6 C D S Number system character Automatically decided according to the combination of each character of X1 t...

Страница 48: ...To enter reading measurement mode using a TEST button on the back side 1 Install the bar code at a reading position 2 Keep pressing the TEST button until the buzzer tones repeating Sol and Do sounds...

Страница 49: ...eading is possible without problem 51 75 When the bar code is at still state when read reading is possible without problem However when the target bar code is moving reading may be failed according to...

Страница 50: ...51 V500 R521B2 C2 User s Manual Section 4 Setting Method This section explains about setting methods using a menu sheet and entering command from the upper equipment How to Use Menu Sheet Command 52 M...

Страница 51: ...he bar code reader entered setting mode 2 Read UA on the menu sheet that means to return to factory default setting 3 Read the item on the menu sheet you want to change setting Menu Sheet Command List...

Страница 52: ...system of CODE39 However the code is special using start code and stop code for a space mark Normally You can create a menu sheet using bar code creation software available in the market as shown bel...

Страница 53: ...the bar code reader is processing command it notifies externally that it is in processing mode turning off the RS signal line When the RS signal line is not connected interval between inputting comma...

Страница 54: ...d 12 digit 00H zero cannot be designated as header or footer It is regarded as end character Characters until just before 00H are valid Transmit a header setting command Transmit a character A Transmi...

Страница 55: ...d prohibition p 61 Detail setting for reading code p 63 Setting for reading conformance p 66 Setting for reading system p 67 Setting for failed reading p 68 Setting for number of reading digit p 69 Se...

Страница 56: ...hout writing the setting in the memory the set content may be deleted Reset Return to the setting which is already written in the nonvolatile memory Setting related to external trigger signal Select p...

Страница 57: ...dition Reading system Trigger reading S8 Reading operation Single reading S0 Reading valid time Trigger 2 sec Y2 Number of reading coincidence Twice Verification once X1 Communication condition Commun...

Страница 58: ...ransfer ST SP of NW 7 abcd abcd F4 ITF STF detail setting Invalid C D of ITF STF G0 Transfer C D of ITF STF G2 Reading condition Reading system Trigger reading S8 Reading operation Single reading S0 R...

Страница 59: ...sfer C D of ITF STF G2 Reading condition Reading system Trigger reading S8 Reading operation Single reading S0 Reading valid time Trigger 2 sec Y2 Number of reading coincidence Twice Verification once...

Страница 60: ...etting J1 Reading permission for UPC A E R1 Reading permission only for EAN13 8 J4 Reading permission for EAN13 8 Factory default setting R4 Reading permission only for CODE39 A2 Reading permission fo...

Страница 61: ...DE128 A6 Reading permission for CODE128 B6 Reading prohibition for EAN UPC 4A Reading prohibition for CODE39 4H Reading prohibition for NW 7 4I Reading prohibition for STF 4K Reading prohibition for I...

Страница 62: ...digit without C D E4 Output UPC A in 12 digit without 0 in the beginning E3 Output UPC A in 11 digit without 0 in the beginning or C D E5 Menu sheet Command Menu sheet Command Output UPC E in 8 digit...

Страница 63: ...setting 7D Menu sheet Command Menu sheet Command Invalid C D of NW 7 Factory default setting F7 Transfer ST SP of NW 7 ABCD ABCD F3 Valid C D of NW 7 modulus 16 F9 Transfer ST SP of NW 7 abcd abcd Fa...

Страница 64: ...Command Menu sheet Command Invalid C D of ITF STF Factory default setting G0 Not transfer C D of ITF STF G3 Valid C D of ITF STF G1 ITF STF 2 digit reading permission 7M Transfer C D of ITF STF Factor...

Страница 65: ...232C interface Verification system is AND verification Continuous conformance system Change prohibition Menu sheet Command Menu sheet Command Reading conformance twice Verification once Factory defaul...

Страница 66: ...m Set the reading system Explanation of Reading System p 36 Reading system Reading operation Menu sheet Command Menu sheet Command Full time reading S7 Trigger reading Factory default setting S8 Menu...

Страница 67: ...it is judged as no bar code In cases other than above Menu sheet Command Menu sheet Command When reading failed no process Factory default setting 5E When reading failed Transfer CR CR 5H When reading...

Страница 68: ...the number of digit you want to register twice continuously When the number of digit is one type set A and B to the same setting 2 After transmitting this command transmit the character string of the...

Страница 69: ...ystem which is required to set the effective duration is selected Explanation of Reading System p 36 Menu sheet Command Menu sheet Command Coupled with trigger trigger 0 sec Y0 Trigger 0 ms minor sett...

Страница 70: ...et Command Trigger 10 sec Y7 Trigger 350 ms minor setting YH Trigger 400 ms minor setting YI Trigger 600 ms minor setting YM Trigger 450 ms minor setting YJ Trigger 650 ms minor setting YN Trigger 500...

Страница 71: ...ng failed READ NG LED illuminates Duration of illumination is allowed to set Menu sheet Command Menu sheet Command LED does not illuminate after decode T4 The LED illuminates for 400 ms after decoding...

Страница 72: ...registered data Buzzer sound volume Duration of buzzer Menu sheet Command Menu sheet Command Buzzer sound volume max Factory default setting T0 Buzzer sound duration after decoding 10 ms W8 Buzzer so...

Страница 73: ...nual Section 4 Setting Method Buzzer frequency Menu sheet Command Menu sheet Command Buzzer sound frequency after decoding 3 kHz W1 Buzzer sound frequency after decoding 2 kHz 3 kHz W3 Buzzer sound fr...

Страница 74: ...ng 8Q Signal output one shot duration 30 ms 8I No signal output 8R Signal output one shot duration 40 ms 8J Signal output trigger signal synchronous system positive logic Factory default setting 8C Si...

Страница 75: ...tion 4 Menu Sheet Command List V500 R521B2 C2 User s Manual Section 4 Setting Method Signal output one shot duration 20 ms 8H Signal output one shot duration 100 ms 8P Menu sheet Command Menu sheet Co...

Страница 76: ...Factory default setting L1 Communication speed 1200 bps K3 No parity Factory default setting L2 Communication speed 2400 bps K4 Parity even number L3 Communication speed 4800 bps K5 Parity uneven num...

Страница 77: ...AK system P3 CS waiting time Infinite Factory default setting I0 Communication protocol No protocol system Factory default setting P5 CS waiting time 100 ms I1 ACK NAK response waiting time Infinite F...

Страница 78: ...Setting related to test reading Test reading function p 49 Menu sheet Command Menu sheet Command Collective setting of header Applied to all codes 1Y Number of reading digit is not transferred Applie...

Страница 79: ...cter strings and values directly such as designation of header and footer or number of reading digit Menu sheet Command Menu sheet Command A is set 0A I is set 0I B is set 0B J is set 0J C is set 0C K...

Страница 80: ...List Section4 Setting Method Q is set 0Q Z is set 0Z R is set 0R 0 is set Q0 S is set 0S 1 is set Q1 T is set 0T 2 is set Q2 U is set 0U 3 is set Q3 V is set 0V 5 is set Q5 W is set 0W 6 is set Q6 Y...

Страница 81: ...4 Menu Sheet Command List V500 R521B2 C2 User s Manual Section 4 Setting Method Menu sheet Command Menu sheet Command 8 is set Q8 ETX 03H is set 1B 9 is set Q9 CR ODH is set 1C STX 02H is set 1A LF 0A...

Страница 82: ...ollows When sorting read function is used do not change the setting basically To change a part of communication condition etc change it after you input command UE and sorting read operation starts Ite...

Страница 83: ...code ESC Q 2 CR Designation of character string 2 direct code ESC Q 3 CR Designation of character string 3 direct code 6 1 CR Designation of character string a 61H 0 0 CR Separation 2 A CR Designatio...

Страница 84: ...B CR Designation of character string 5BH ESC 0 A CR Designation of character string A direct code 7 C CR Designation of character string 7CH ESC 0 F CR Designation of character string F direct code 5...

Страница 85: ...ction 5 Example of System Configuration This section explains about connection method with upper equipment Example of Connection with a PC 88 Example of Connection with Programmable Controller CS1 89...

Страница 86: ...PUT 1 1 150 IF AA CHR H03 GOTO 170 160 BCDATA BCDATA AA GOTO 140 170 PRINT READ DATA BCDATA 180 GOTO 130 Special cable V509 W011D Bar code reader V500 R521C2 AC 100 V Power supply for bar code S8VS 01...

Страница 87: ...CPU unit Wire When V500 R521B2 is used Special cable V509 W011 Bar code reader V500 R521C2 100 VAC Power supply for bar code S8VS 01505 Power supply unit C200HW PA204S CPU unit CS1H CPU64 V1 Input un...

Страница 88: ...ation manual of your programmable controller Setting item Setting content Command Communication speed 9600 bps Same as initial setting Data length 7 bit L0 Parity Even number L3 Stop bit 2 bit L6 Head...

Страница 89: ...d To check the read data with the programming console press Clear FUN Monitor in this order For the program command refer to the operation manual of your programming console Items related to communica...

Страница 90: ...ing to the interface RS 485 or RS 232C of the upper equipment side Example of connecting communication link unit hereinafter referred to as link unit and the upper equipment using RS 485 is described...

Страница 91: ...s Same as initial setting Data length 8 bit Same as initial setting Parity Even number L3 Stop bit 1 bit Same as initial setting Header None Same as initial setting Footer CR Same as initial setting R...

Страница 92: ...d from the upper equipment the link unit transmits the stored read data to the upper equipment Communication converter PC AT compatible PC Execution of reading Link unit Machine No 01 Machine No 02 Ma...

Страница 93: ...equipment E g When exporting data of machine No 2 Reading data transmitted from the bar code reader E g When the reading data of the machine No 2 is ABCDE E g When the read data is not accumulated Whe...

Страница 94: ...bar code reader and the link unit is described here When used be sure to read the operation manual of the link unit V700 L12 LED Description RUN Illuminate during normal operation of the link unit CO...

Страница 95: ...At operation 0 to 45 C At storage 15 to 50 C without freeze or dew condensation Ambient humidity At operation and storage 35 to 85 RH without due condensation Enclosure rating IP20 IEC60529 Standard...

Страница 96: ...is a power terminal The terminal mounting screw size is M3 Use a crimping terminal which fits to M3 screw Connect 24 V power supply device Recommended device Shape Size Fork type Round type Manufactur...

Страница 97: ...9 OFF OFF ON ON ON 14 ON OFF ON ON OFF 30 ON OFF ON ON ON 15 OFF ON ON ON OFF 31 OFF ON ON ON ON 16 ON ON ON ON OFF Setting not allowed ON ON ON ON ON Setting item Initial setting Description Communic...

Страница 98: ...ormat fixed Start bit Data bit Parity bit Stop bit Total 1 8 None 1 10 Check code Error detection system FCS Frame Check Sequence Vertical parity system PinNo Signal name Function Signal direction 1 N...

Страница 99: ...or link unit side 2 When CS function is used on PC side a return line is required Model Manufacturer Cable CO MA VV SB 5PX28AWG Hitachi Cable Ltd Connector Socket XM2D 0901 OMRON Corporation Hood XM2...

Страница 100: ...munication system In compliance with RS 485 Synchronous system Asynchronous system Communication control system One to N procedure dedicated to OMRON Communication speed 4800 9600 19200 38400 bps Set...

Страница 101: ...line MVVS 2CX0 5SQ Tachii Electric Wire Co Ltd Frame ground wire Cables of AWG22 to 20 Crimping terminal When connecting one wire to one terminal AI0 5 8WH PHOENIX CONTACT When connecting two wires t...

Страница 102: ...chronous system Asynchronous system Communication control system One to one procedure dedicated to OMRON Communication speed fixed 9600 bps Character format fixed Start bit Data bit Parity bit Stop bi...

Страница 103: ...to transmit to the bar code reader However in case when the first character is DLE 10 h it is handled as link unit process command defined by the next character P 50 h Polling Invalid in case of throu...

Страница 104: ...there is no data in buffer In case of Through procedure normal output procedure no response is output even if command is input Resend request R The response sent before is transmitted again Input comm...

Страница 105: ...on frame with the bar code reader to STX to ETX Y Input command Response When a code other than 00 is returned p 110 Communication frame with the bar code is as shown below However it returns to defau...

Страница 106: ...erformed for normal operation Upper equipment RS 232C 24 V power source 24 V power source 24 V power source 24 V power source Bar code reader Bar code reader Bar code reader Bar code reader DIP SW 1 t...

Страница 107: ...e performed for normal operation Upper equipment 24 V power source 24 V power source 24 V power source 24 V power source Bar code reader Bar code reader Bar code reader Bar code reader DIP SW 1 to 5 S...

Страница 108: ...he command and the machine No setting on the link unit side Command format CR calculation of check codes distance of command characters etc RS 232C cable wiring effect of circumference noise There are...

Страница 109: ...es are returned as a response error occurred Check by referring following table End code Error cause Check point 93 Bar code reader communication malfunction Cable wiring of the bar code reader effect...

Страница 110: ...Section 6 Appendix 113 V500 R521B2 C2 User s Manual Section 6 Appendix External Dimension 114 Troubleshooting 120 ASCII Code Table 121 Explanation of Terms 122 Corresponding Bar Code List 127...

Страница 111: ...on V500 R521B2 C2 User s Manual Section 6 Appendix External Dimension Bar code reader V500 R521B2 Unit mm Light axis 2 M3 Depth 4 5 or less Vinyl insulated round cord 3 8 9 core Black Standard length...

Страница 112: ...Manual Section 6 External Dimension Section 6 Appendix Bar code reader V500 R521C2 Unit mm Light axis 2 M3 Depth 4 5 or less Vinyl insulated round cord 3 8 9 core Black Standard length 2 m Bar code l...

Страница 113: ...round cord 5 1 Pink external trigger Brown 5V Blue 0V Vinyl insulated round cord 3 8 3 core conductor section area 0 2 mm2 diameter of insulation body 1 0 mm Signal name No FG 1 SD 2 RD 3 RS 4 CS 5 6...

Страница 114: ...al trigger Brown 5V Blue 0V Vinyl insulated round cord 4 7 3 core conductor section area 0 2 mm2 diameter of insulation body 1 0 mm Signal name No 1 RD 2 SD 3 ER 4 SG 5 DR 6 RS 7 CS 8 9 Shield wire Co...

Страница 115: ...external trigger Blue 0V Vinyl insulated round cord 3 8 2 core conductor section area 0 2 mm2 diameter of insulation body 1 0 mm Signal name No 1 SD 2 RD 3 RS 4 CS 5 5V 6 0V 7 8 SG 9 Shield wire Conn...

Страница 116: ...119 V500 R521B2 C2 User s Manual Section 6 External Dimension Section 6 Appendix Communication link unit V700 L12 Unit mm Dimension of mounting hole process 2 M4 or 4 2 2 4 5...

Страница 117: ...tion setting content Especially check the operation mode and data output mode 2 Is the bar code mounted or does it pass at the reader reading position 3 Are there enough margin on both sides of the ba...

Страница 118: ...4 ENQ 05 25 E 45 e 65 ACK 06 26 F 46 f 66 BEL 07 27 G 47 g 67 BS 08 28 H 48 h 68 HT 09 29 I 49 i 69 LF 0A 2A J 4A j 6A VT 0B 2B K 4B k 6B FF 0C 2C L 4C l 6C CR 0D 2D M 4D m 6D S0 0E 2E N 4E n 6E S1 0F...

Страница 119: ...Number of conformance should be at least twice number of verification is once to increase reliability Narrow bar slim bar The narrower bar in the bar code consists with horizontal bars is called a na...

Страница 120: ...ht 1 Add the digits in the even positions the rightmost character is the 1st digit and multiple it by 3 2 Add up the odd numbers excluding the rightmost check digit in the data digit 3 Add values of a...

Страница 121: ...Table 1 Table 1 Character value calculated in Modulus 43 E g When message CODE39 is indicated in CODE39 Therefore data with check character is CODE39R Character Value Character Value Character Value...

Страница 122: ...In other cases take the reminder value from 16 and the result is the check character value 4 Result of clause 3 is the check character value shown in table 2 Table 2 Character value calculated in Modu...

Страница 123: ...reflection ratio is 85 or more RS CS control Control system to communicate data between the bar code reader and the upper equipment Data is transmitted while verifying to hardware through RS CS line w...

Страница 124: ...127 V500 R521B2 C2 User s Manual Section 6 Corresponding Bar Code List Section 6 Appendix Corresponding Bar Code List EAN UPC CODE39 STF NW 7 CODE93 ITF CODE128...

Страница 125: ...system 36 External dimension figure 33 114 External trigger signal 29 30 36 57 F Flow chart 38 Footer 79 Full time reading 36 67 H Header 79 Height 9 I ID connection port 104 Immediate transmission s...

Страница 126: ...measurement mode 49 Reading system 36 67 Reading time 42 Reading trigger 46 Reading window 19 Regular expression 84 Reset 57 RS CS control 77 126 RS 232C command 36 S Setting end 57 Setting start 57 S...

Страница 127: ...ription in Warning display P20 Changed information in General Specification P21 Deleted Number of digit in table P30 Changed model number of recommended parts P33 Added information to diagram for insu...