Appendix D
Programming Console Operations
145
Name
Page
Basic key sequences
Modes
Filter Value
Designation
PRGM
only
Used to adjust the input read filter time.
Each group can be set to 0 ms, 1 ms,
5 ms, or 10 ms. Set all three groups at
the same time.
Factory settings are 10 ms.
Group 1
CLR
FUN
1
2
3
ENT
6
0
5
1
2
3
ENT
0
(0ms)
(0ms)
Group 2
(1ms)
(5ms)
(10ms)
(1ms)
(5ms)
(10ms)
SP10
0 to 2
3 to 5
None
SP16
0 and 1
2 to 5
6 to 9
SP20
0 and 1
2 to 9
10 and 11
Group 1
Group 2
Group 3
PC
1
2
3
ENT
0
(0ms)
Group 3
(1ms)
(5ms)
(10ms)
22
Filter Value
Read
RUN or
PRGM
Used to read the filter time. When performed
with the SP10-PRO01-V1, both the PC and
Programming Console settings are displayed.
CLR
FUN
6
6
MON
22
PC
Designation
RUN or
PRGM
Used to designate the PC being accessed when a
Link Adapter is used to link multiple PCs. (Factory
set to 0.)
PC no. (0 to 3)
MON
CLR
FUN
6
7
1
2
3
0
52
Instruction
Insert
PRGM
only
Used to insert an instruction at the
address currently being displayed.
Address Designation
Program Read
Instruction
INS
61
Instruction
Delete
PRGM
only
Used to delete the instruction being displayed.
Address Designation
Program Read
DEL
61
Status
Monitor
RUN
only
Used to monitor status in
RUN mode.
Moves to preceding
address.
Moves to next
address.
Address Designation
54
Bit/Word
Monitor
RUN or
PRGM
Used to monitor I/O
bits, other bit status,
word status, or TC PV.
Cancels
monitoring.
TIM
CNT
CLR
MON
SHIFT
SHIFT
LD
DR
CLR
SHIFT
MON
LD
OUT
CONT
#
CH
*
Program Read
Bit
address
Scroll the
address being
monitored.
Word monitor
116
Multibit/
Word
Monitor
RUN or
PRGM
Used to expand Bit/Word
Monitor to up to three bits,
words, and/or TC PV.
Scrolls the display.
Scroll the
address being
monitored.
Cancels one bit.
Cancels all monitoring.
TIM
CNT
CLR
MON
SHIFT
SHIFT
CH
*
LD
DR
CLR
MON
CLR
SHIFT
CONT
#
Bit/Word Monitor
Bit
address
116