11
Overall Operating Procedure
Section 1-4
1-4
Overall Operating Procedure
1-4-1
Inverters
No.
Step
Operations
1
Install the software. Install the CX-Server and CX-Drive from the CX-
One.
Refer to the
CX-One Ver. 2.1 Setup
Manual
(Cat. No. W463).
2
Connect the drive
to the computer.
Connect the CX-Drive (computer) to the drive
(Inverter or Servo) using one of the system
configurations.
Refer to
1-3 System Configuration
.
3
Start the CX-Drive. ---
Select
Program - OMRON - CX-One -
CX-Drive - CX-Drive
from the
Windows Start Menu.
4
Create a new drive
file.
Method 1
Detect the drives connected online automatically
and create drive file for the desired drive.
Select
File - Autodetect
from the
menu bar.
Method 2
Create a new drive
file on the computer
without a drive.
Select
Inverter
as the drive
type and then select one of
the following series.
•
3G3JV
•
3G3MV
•
3G3RV (See note.)
Select
File - New
from the menu bar
and then select the drive type in the
New Drive Dialog Box.
Note
For version 1 of the 3G3RV, click
the
Settings
Button and select
-V1
for the
Specification
.
Select one of the following
connection types.
•
Direct
•
Via PLC (SCU/SCB)
•
Via PLC (DeviceNet)
Select the connection type in the New
Drive Dialog Box.
5
Edit the
parameters.
Edit the parameters for the Inverter.
Edit parameters in numeric order or by functional
category.
In the Workspace, double-click
Parameter edit
and then the required
categories in the drive file.
6
Connect online to
the drive.
---
Select
Drive - Work Online
from the
menu bar.
7
Transfer and verify
the parameters.
---
Select
Drive - Transfer - To drive
from
the menu bar.
8
Tune and test
operation.
Test Run
Perform the following:
Forward/reverse operation,
stopping, frequency
references, acceleration/
deceleration, S-curve display,
and dwelling.
Double-click
Test Run
in the
Workspace.
Auto Tune
(3G3RV only)
Enter the motor parameters,
perform auto-tuning, and
then save the new
parameters.
Double-click
Auto Tune
in the
Workspace.
9
Monitor operation.
Perform a Real Time Trace.
Double-click
Real Time Trac
e
in the
Workspace.
Check the status.
Double-click
Status
in the Workspace.
10
Save the data.
Save the Workspace and/or the drive file
Select
File - Save Workspace
, or
select
File - Save as Workspace
…
Содержание SYSMAC CXONE-ALC-EV2 Series
Страница 1: ...CX Drive Cat No W453 E1 05 SYSMAC CXONE AL C EV2 CXONE AL D EV2 OPERATION MANUAL...
Страница 2: ...CXONE AL C EV2 CXONE AL D EV2 CX Drive Operation Manual Revised June 2007...
Страница 3: ...iv...
Страница 5: ...vi...
Страница 7: ...viii TABLE OF CONTENTS...
Страница 13: ...xiv...
Страница 17: ...xviii Application Precautions 4...
Страница 51: ...34 Editing Drive Files Section 2 4...
Страница 53: ...36 Revision History...