12
Input and output cables can be differentiated by position, as shown on the
right below. Alignment with the connector pin numbers is also as shown on
the left below. Please make sure you are wiring to the correct pins.
Input cables
Output cables
Connector pins as viewed
from the solder side.
Pin number
marks
Shape of connector
on the reverse side.
Assembling Connectors
Assemble connectors as shown below.
Connector
Round head screw
(8mm M2, two total)
Nut (M2, four total)
Round head screw
(10mm M2, two total)
Case
Lock screw
Note Any of the following connectors can be used as required by operating condi-
tions. The jack is a Fujitsu model 360.
1, 2, 3... 1.
FCN-361J040 (solder-type, included with Counter Unit)
FCN-360C040-B (connector cover)
2.
FCN-363J040 (crimp type, housing)
FCN-363J-AU (connector)
FCN-360C040 (connector cover)
3.
FCN-367J040-AV/F (crimp type)
Wiring Precautions
For the C200H-CT001-V1, the terminals that are used depend upon the pow-
er supply of inputs A, B, and Z.
For the C200H-CT002, inputs A, B, and Z must be line driver inputs
(Am26LS31-compatible). Positive and negative terminals must be wired cor-
rectly. The terminals that are used depend upon the power supply of the control
inputs. Be careful to connect to the correct terminals. Supply only one voltage for
Differentiating Cables and
Connector Pin Numbers
Wiring
Section 2-2
Содержание SYSMAC C200H-CT001-V1
Страница 1: ...Cat No W141 E1 4 High speed Counter Units SYSMAC C200H CT001 V1 CT002 OPERATION MANUAL...
Страница 2: ......
Страница 3: ...C200H CT001 V1 CT002 High speed Counter Units Operation Manual Revised September 2000...
Страница 4: ...iv...
Страница 6: ...vi...
Страница 8: ......
Страница 10: ......
Страница 20: ......
Страница 46: ......
Страница 96: ......
Страница 98: ......