5-12
n28
Frequency Reference 8
Changes during
operation
Yes
Setting
range
0.0 to max. frequency
Unit of
setting
0.01 Hz
(see note 1)
Default setting
0.0
Note 1. Values will be set in 0.1-Hz increments if the frequency is less than 100 Hz and
1-Hz increments if the frequency is 100 Hz or over.
Note 2. Frequency reference 1 is enabled with n03 for frequency reference selection
set to 1.
Note 3. Frequency references 2 through 8 are enabled by setting multi-step speed ref-
erences 1, 2, and 3 in n36 through n39 for multi-function input. Refer to the fol-
lowing table for the relationship between multi-step speed references 1 through
3 and frequency references 1 through 8.
Frequency reference
Multi-step speed
reference 1
(Set value: 6)
Multi-step speed
reference 2
(Set value: 7)
Multi-step speed
reference 3
(Set value: 8)
Frequency reference 1 OFF
OFF
OFF
Frequency reference 2 ON
OFF
OFF
Frequency reference 3 OFF
ON
OFF
Frequency reference 4 ON
ON
OFF
Frequency reference 5 OFF
OFF
ON
Frequency reference 6 ON
OFF
ON
Frequency reference 7 OFF
ON
ON
Frequency reference 8 ON
ON
ON
No multi-step speed reference 3 settings will be required if only frequency references 1
through 4 are used, for example. Any multi-step speed reference not set is regarded as
turned-OFF input.
D
Setting the Inching Frequency Command (n29)
•
The inching frequency command must be set as multi-function input in order to use the
inching frequency command.
n29
Inching Frequency Command
Changes during
operation
Yes
Setting
range
0.0 to max. frequency
Unit of
setting
0.01 Hz
(see note 1)
Default setting
6.0
Note 1. The value will be set in 0.1-Hz increments if the frequency is less than 100 Hz
and 1-Hz increments if the frequency is 100 Hz or over.
Basic Operation
Chapter 5
Содержание SYSDRIVE 3G3JV-AB001
Страница 1: ...USER S MANUAL FIRST DRAFT SYSDRIVE 3G3JV Compact Simplified Inverter Cat No I528 E1 1...
Страница 3: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1...
Страница 9: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Страница 43: ...Chapter 3 Preparing for Operation and Monitoring 3 1 Nomenclature 3 2 Outline of Operation 3...
Страница 52: ...3 10 Preparing for Operation and Monitoring Chapter 3...
Страница 53: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Страница 62: ...4 10 Test Run Chapter 4...
Страница 131: ...7 22 Maintenance Operations Chapter 7...
Страница 132: ...Chapter 8 Specifications 8 1 Inverter Specifications 8 2 Option Specifications 8...
Страница 138: ...Chapter 9 List of Parameters 9...
Страница 150: ...Chapter 10 Using the Inverter for a Motor 10...
Страница 165: ...Revision History 10 2...
Страница 166: ...Cat No I528 E1 1 SYSDRIVE 3G3JV Compact Simplified Inverter USER S MANUAL...