![Omron SYSDRIVE 3G3JV-AB001 Скачать руководство пользователя страница 141](http://html1.mh-extra.com/html/omron/sysdrive-3g3jv-ab001/sysdrive-3g3jv-ab001_user-manual_742834141.webp)
9-4
Parame-
ter No.
Refer-
ence
page
Changes
during
opera-
tion
Default
setting
Unit
of set-
ting
Set-
ting
range
Description
Name
n20
S-shape accel-
eration/decel-
eration charac-
teristic
Used to set S-shape acceleration/decel-
eration characteristics.
0: No S-shape acceleration/deceleration
(trapezoidal acceleration/deceleration)
1: S-shape acceleration/deceleration char-
acteristic time 0.2 s
2: S-shape acceleration/deceleration char-
acteristic time 0.5 s
3: S-shape acceleration/deceleration char-
acteristic time 1.0 s
Note
When the S-shape acceleration/de-
celeration characteristic time is set,
the acceleration and deceleration
times will be lengthened according to
the S-shape at the beginning and
end of acceleration/deceleration.
0 to 3
1
0
No
n21
Frequency ref-
erence 1
Used to set internal frequency references.
Note
Frequency reference 1 is enabled in
0.0 to
max.
fre
0.1 Hz
(see
note)
6.0
Yes
5-11
n22
Frequency ref-
erence 2
Note
Frequency reference 1 is enabled in
remote mode with n03 for frequency
reference selection set to 1.
max.
fre-
quen-
cy
(see
note)
0.0
Yes
5-11
n23
Frequency ref-
erence 3
reference selection set to 1.
Note
These frequency references are se-
lected with multi-step speed refer-
cy
0.0
Yes
5-11
n24
Frequency ref-
erence 4
lected with multi step speed refer
ences (multi-function input). See the
reference pages for the relationship
b t
lti t
d
f
0.0
Yes
5-11
n25
Frequency ref-
erence 5
p g
p
between multi-step speed refer-
ences and frequency references.
0.0
Yes
5-11
n26
Frequency ref-
erence 6
0.0
Yes
5-11
n27
Frequency ref-
erence 7
0.0
Yes
5-11
n28
Frequency ref-
erence 8
0.0
Yes
5-11
n29
Inching fre-
quency com-
mand
Used to set the inching frequency com-
mand.
Note
The inching frequency command is
selected with the inching command
(multi-function input). The inching
frequency command takes prece-
dence over the multi-step speed ref-
erence.
6.0
Yes
n30
Frequency ref-
erence upper
limit
Used to set the upper and lower frequency
reference limits in percentage based on
the maximum frequency as 100%.
Note
If n31 is set to a value less than the
minimum output frequency (n14) the
0 to
110
1%
100
No
n31
Frequency ref-
erence lower
limit
minimum output frequency (n14), the
Inverter will have no output when a
frequency reference less than the
minimum output frequency input is
input.
0 to
110
1%
0
No
List of Parameters
Chapter 9
Содержание SYSDRIVE 3G3JV-AB001
Страница 1: ...USER S MANUAL FIRST DRAFT SYSDRIVE 3G3JV Compact Simplified Inverter Cat No I528 E1 1...
Страница 3: ...Chapter 1 Overview 1 1 Function 1 2 Nomenclature 1...
Страница 9: ...Chapter 2 Design 2 1 Installation 2 2 Wiring 2...
Страница 43: ...Chapter 3 Preparing for Operation and Monitoring 3 1 Nomenclature 3 2 Outline of Operation 3...
Страница 52: ...3 10 Preparing for Operation and Monitoring Chapter 3...
Страница 53: ...Chapter 4 Test Run 4 1 Procedure for Test Run 4 2 Operation Example 4...
Страница 62: ...4 10 Test Run Chapter 4...
Страница 131: ...7 22 Maintenance Operations Chapter 7...
Страница 132: ...Chapter 8 Specifications 8 1 Inverter Specifications 8 2 Option Specifications 8...
Страница 138: ...Chapter 9 List of Parameters 9...
Страница 150: ...Chapter 10 Using the Inverter for a Motor 10...
Страница 165: ...Revision History 10 2...
Страница 166: ...Cat No I528 E1 1 SYSDRIVE 3G3JV Compact Simplified Inverter USER S MANUAL...