Troubleshooting
PROGRAMMING MANUAL
343
R
e
vi
si
o
n
1
.0
To enable the errors, type
COORDINATOR_DATA(7,0)
in the Trajexia
Studio terminal window.
To see the current setting, type
PRINT COORDINATOR_DATA(7)
in the
Trajexia Studio terminal window.
To clear the error after repair do these steps:
•
Reconnect the lost MECHATROLINK-II I/O unit or Inverter.
•
Type
MECHATROLINK(n, 5, station, -1)
in the Trajexia Studio terminal
window:
where
n
is the number of the TJ1-ML__ to which the MECHATROLINK-II
unit affected, and
station
is the MECHATROLINK-II device number that
is lost.
If you want to use the system without the lost device, you can reconnect all
available devices on the TJ1-ML__. To do this, type
MECHATROLINK(n, 0)
in the Trajexia Studio terminal window, where
n
is the number of the TJ1-
ML__ that reports the error.
TJ1-ML__ version not supported
TJ2-MC64 requires TJ1-ML__ units with a minimum FPGA version 18. The
FPGA version can be checked by typing
PRINT FPGA_VERSION SLOT(x)
in the Trajexia Studio terminal window. Replace x with the position of the
TJ1-ML__ unit, starting from 0.
No terminator
The error code
U07
shows on the display.
To solve the problem, check the terminator connection or replace the
terminator if it is defective.
Too many units connected
The error code
U07
shows on the display.
To solve the problem, check the number of connected units. No more than 7
units are supported.
6.2.4
Configuration errors
Configuration errors show on the LED display of the TJ2-MC64 as
Cnn
.
/i
6.2.5
Replace the battery
To replace the backup battery, do these steps:
1. Make sure the Power Supply Unit is set to on for at least five minutes. If
not, the capacitor that backs up the memory of the TJ2-MC64 while the
battery is not connected is not fully charged, and you can lose data in
memory.
2. Pull the top of the lid of the battery compartment away from the unit to
open the battery compartment.
3. Pull the red and white wires to pull out the old battery.
4. Make sure you complete the next 2 steps within 30 seconds to prevent
data loss in the RAM memory.
5. Disconnect the wires from the old battery.
6. Attach the wires to the new battery.
7. Insert the new battery into the battery compartment.
8. Close the lid of the battery compartment.
Error
code
Description
Cause
Solution
Cnn
Configuration
error caused
by unit nn
The system has too many units of the
same type, and it does not adhere to
the rules for adding units to a system
Change the system so
that it adheres to the
rules for adding units to
a system. See the Hard-
ware Reference manual.
You have connected too many MECHA-
TROLINK-II stations to the TJ1-ML__
There are too many axes in the system
There are too many non-axis MECHA-
TROLINK-II stations in the system
AXIS_OFFSET is non-zero for a unit
not supporting axes (e.g. TJ1-PRT)
Change AXIS_OFFSET