Directions for safe use
Explanations
Usual operating method
●
You may keep the UPS running without making a stop, or you may turn off the UPS at each time when the
devices connected the UPS is turn off.
You can choose either of two ways at your convenience.
●
Putting the UPS to a wall outlet (commercial power) starts charging the battery.
Terminating the backup mode
●
In a case where power failure continues longer, the battery keeps its discharging and finally the UPS stops
sending power. Before that, turn off your computer in the usual manner (including data backup).
Reboot
●
If the battery discharges completely during a power failure, the UPS stops. After the recovery from a failure
of the power supply (for example, power failure), the UPS automatically restarts and starts to feed power. If
you do not want to run the devices connected to the UPS, keep turning the devices off.
●
The UPS monitoring software permits to disable automatic restart.
Scheduled operating mode through the UPS monitoring software
●
When performing scheduled operating mode in which the UPS is turned off and the commercial power is cut
off by using a circuit breaker at the same time, specify a less than 3 months shutdown. In a case that you
specify the shutdown longer than 3 months, the internal timer will be reset and the scheduled operating
mode will not work.
Notice that a shutdown should reduce to approximately half where the battery is dead.
In a case where a shutdown exceeds 3 months, the UPS starts to feed commercial power and you can get
the UPS running by pressing the Start switch. However, if the battery is already dead, you may not be able
to start the UPS. Then replace the battery according to "6-2 Replacing the battery" on page 33.
Installing a rack
●
For safety installation, placing a rail or steel plate is recommended to support the weight of the USP.
●
The weight of the UPS
BU100XR2: 19kg
BU200XR2: 12kg (main unit)
MB100XR2: 26kg (add-on battery unit)
MB200XR2: 26kg (battery unit)
●
Place the UPS on the lowest part of lack. When connecting the battery unit and/or adding another battery
unit, be sure to place the battery unit on the lower part of main unit.
Notes
Recycling and Discarding the Battery
●
The UPS has a lead acid battery. The battery is recyclable, and precious resource. We need
your cooperation in recycling the old batteries; the batteries you replace with a new battery,
and the batteries you used to discard.
●
For further information on recycling and/or discarding of batteries and UPS, please contact us;_________.
Installation and storage places
●
Do not install or store the UPS in a place exposed to direct sunlight.
The rise of temperature may cause the battery to deteriorate and become unusable.
Pb