background image

 
 
 
 
 
 
 

 

 
 
 
 
 
 
 

Uninterruptible Power Supply 

 

ERA LCD 0.65 Rack Mount 

ERA LCD 0.85 Rack Mount 

ERA LCD 1.1 Rack Mount 

 

 

User’s manual 

U.T.E. Electronic GmbH & Co. KG - Friedrich-Ebert-Str. 112a - 58454 Witten (Germany)
          Tel.: 02302-282830 - Email: [email protected] - Internet: www.ute.de

Содержание ERA LCD 0.65 Rack Mount

Страница 1: ...Supply ERA LCD 0 65 Rack Mount ERA LCD 0 85 Rack Mount ERA LCD 1 1 Rack Mount User s manual U T E Electronic GmbH Co KG Friedrich Ebert Str 112a 58454 Witten Germany Tel 02302 282830 Email info ute d...

Страница 2: ...rst Start Up 7 6 Functioning 8 6 1 Normal Mode 8 6 2 Battery Mode 8 6 3 Low Battery and Automatic Restart 8 6 4 Load Control 8 6 5 Fault Condition 9 7 Communication Interface 9 8 Technical Characteris...

Страница 3: ...main powered and therefore dangerous even after the UPS has been disconnected from AC power mains Before any repair or maintenance work disconnect the batteries by removing the positive cable red colo...

Страница 4: ...low battery condition directly to a computer this makes it possible to automatically save your data during an extended black out with the most widespread operating systems Windows Linux etc Read this...

Страница 5: ...y Maximum reliability Smart design and easy to use 3 Receipt and site selection Carefully remove the UPS from its packaging and carry out a meticulous inspection We recommend keeping the original pack...

Страница 6: ...ditions and measurements Front panel shown below consists of two parts 1 LCD display provides information about input only in line mode and output voltage output frequency only in battery mode battery...

Страница 7: ...oltage 3 BATTERY LEVEL 3 digits indicate the battery charging percentage 4 LOAD LEVEL 3 digits indicates the output load percentage 5 FREQUENCY the 3 digits indicate the output frequency only visualiz...

Страница 8: ...IEC C13 type black colour to supply critical loads 3 Telephone protection RJ11 IN OUT connectors to protect and filter a phone line TNV 3 type connections 4 Computer Interface DB9 female connector it...

Страница 9: ...eover be sure that all the devices connected to the UPS outputs are working correctly By LCD display check if the Output load percentage is less than 100 otherwise it is necessary to remove part of th...

Страница 10: ...matically thus preventing the batteries from discharging excessively the UPS stops supplying Output power deactivates control panel indication and goes to a waiting state Once AC Input comes back on t...

Страница 11: ...e UPS rear side there are the connectors of the Interfaces Only one of the RS232 USB communications can be activated at one time To activate RS232 communication it is sufficient to connect the RS232 c...

Страница 12: ...Voltage Directive CEI EN 62040 2 2006 EMC Directive Efficiency 92 Battery Type Lead acid sealed free maintenance Number of batteries 1 Nominal Battery Voltage 12 Vdc Battery Specifications 12 Vdc 7 Ah...

Страница 13: ...nd that batteries are recharged automatically if the UPS works in Normal mode or if the UPS is off and connected to the AC Input Line Battery life strongly depends on the ambient temperature There are...

Страница 14: ...CAUTION Do not dispose of batteries in a fire The batteries may explode CAUTION Do not open or mutilate batteries Released electrolyte is harmful to the skin and eyes It may be toxic 9 4 Operator Safe...

Страница 15: ...Service The UPS always function in Battery mode Input mains power cable is disconnected Check the input mains power cable Check the presence of the electrical mains ON OFF switch Check if the rear ON...

Страница 16: ...disposed as an urban waste but must be treated as a separate waste Any violation is indictable with financial sanctions as per in force regulations An incorrect waste disposal or an improper use of t...

Отзывы: