The following table describes these indicators.
Indicator
Color
Status
Meaning
RUN
Green
Lit.
The CPU Unit is in normal operation in RUN mode. (The user
program is in execution.)
Flashing
at 2-s
intervals,
then flashing
at 0.5-s
intervals.
The CPU Unit is starting (entering RUN mode or PROGRAM
mode at startup).
Flashing
at 2-s
intervals
continues for
30 seconds or
longer.
System initialization error occurs.
Not lit.
Operation is stopped in PROGRAM mode, when a CPU Unit
reset is in progress, or when any of the following errors occurs.
• Controller error in the major fault level
• CPU error (WDT error)
ERROR
Red
Lit.
Self-diagnosis found one of the following errors.
• Controller error in the major fault level
• CPU error
Flashing
at 1-s
intervals.
Self-diagnosis found one of the following errors.
• Controller error in the partial fault level (an error in which all
control of a Function Module is disabled)
• Controller error in the minor fault level (an error in which partial
control of a Function Module is disabled)
CPU Unit operation will continue for either of these errors.
Operation will stop for the Function Module in which a Controller
error in the partial fault level occurred.
Operation will continue for the Function Module in which a Con-
troller error in the minor fault level occurred.
Not lit.
The CPU Unit is in normal operation, a CPU reset is in progress,
or monitored information occurred. (CPU Unit operation will con-
tinue.)
BUSY
Yellow
Flashing
Built-in non-volatile memory access in progress.
Not lit.
Other than the above.
SD PWR
Green
Lit.
Power is being supplied to the SD Memory Card and the SD
Memory Card can be used.
Flashing
A backup, restore or verification operation is in progress.
*1
*1. Refer to the
NJ/NX-series CPU Unit Software User’s Manual
(Cat. No. W501) for details on backing up data.
Not lit.
The power supply for the SD Memory Card is stopped, an SD
Memory Card is not mounted, or the file format of the mounted
SD Memory Card is not supported.
SD BUSY
Yellow
Flashing
SD Memory Card access in progress.
Not lit.
SD Memory Card access not in progress.
Содержание NX701-1620
Страница 11: ...9 Manual Structure NX series CPU Unit Hardware User s Manual W535...
Страница 46: ...Sections in this Manual 44 NX series CPU Unit Hardware User s Manual W535...
Страница 64: ...1 Introduction to NX series Controllers 1 18 NX series CPU Unit Hardware User s Manual W535...
Страница 72: ...2 System Configuration 2 8 NX series CPU Unit Hardware User s Manual W535...
Страница 90: ...3 Configuration Units 3 18 NX series CPU Unit Hardware User s Manual W535...
Страница 156: ...6 Inspection and Maintenance 6 14 NX series CPU Unit Hardware User s Manual W535...
Страница 163: ...I 1 I NX series CPU Unit Hardware User s Manual W535 Index...
Страница 166: ...I 4 NX series CPU Unit Hardware User s Manual W535 Index...
Страница 167: ......