![Omron NX-EC0112 Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/omron/nx-ec0112/nx-ec0112_user-manual_742777047.webp)
1 - 11
1 Features and System Configuration
NX-series Position Interface Units User’s Manual (W524)
1-2 Syst
em C
o
n
figu
ratio
n
1
1
-2-2
S
ystem Configur
ation When
Connectin
g to a
Cont
roller
Oth
er Th
an the NJ/NX-ser
ies Contr
oller
To use the Position Interface Units, mount them in an EtherCAT Slave Terminal and connect the Termi-
nal to the EtherCAT master of the controller.
You can connect a Pulse Output Unit only to an NJ/NX-series Controller.
(F)
ESI (EtherCAT Slave
Information) file
The ESI file contains information that is unique to the EtherCAT Slave Terminal in XML for-
mat. You can load the ESI file into the Sysmac Studio to easily allocate Slave Terminal pro-
cess data and make other settings.
The ESI files for OMRON EtherCAT slaves are installed in the Sysmac Studio. You can
obtain the ESI files for the latest models through the Sysmac Studio’s automatic update
function.
(G)
Communications
cable
(Ethernet cable)
Use a double-shielded cable with aluminum tape and braiding of category 5
(100BASE-TX) or higher, and use straight wiring.
*1. An EtherCAT Slave Terminal cannot be connected to any of the OMRON CJ1W-NC[]81/[]82 Position Control Units even
though they can operate as EtherCAT masters.
1-2-2
System Configuration When Connecting to a Controller Other
Than the NJ/NX-series Controller
Letter
Item
Description
(A)
EtherCAT master
The EtherCAT master manages the EtherCAT network, monitors the status of the slaves,
and exchanges I/O data with the slaves.
(B)
EtherCAT Coupler
Unit (NX-ECC20
)
The EtherCAT Coupler Unit is an interface that performs process data communications
over an EtherCAT network between the NX Units and the EtherCAT master.
The I/O data for the NX Units is accumulated in the EtherCAT Coupler Unit and then all of
the data is exchanged with the EtherCAT master at the same time.
The EtherCAT Coupler Unit can also perform message communications (SDO communi-
cations) with the EtherCAT master.
(C)
NX Units
The NX Units perform I/O processing with connected external devices.
Process data communications with the EtherCAT master are performed through the Ether-
CAT Coupler Unit.
(D)
End Cover
The End Cover is attached to the end of the Slave Terminal.
Letter
Item
Description
.xml
.xml
(E)
(F)
(A)
(B)
(D)
(G)
(E)
(F)
(C)
Connection to the peripheral USB
port on an EtherCAT Coupler Unit
Peripheral USB port
EtherCAT Slave Terminal
Connection to the Controller
Settings and monitoring tools for
the connected Controller
EtherCAT port
Содержание NX-EC0112
Страница 13: ...11 Manual Structure NX series Position Interface Units User s Manual W524...
Страница 34: ...Revision History 32 NX series Position Interface Units User s Manual W524...
Страница 36: ...Sections in this Manual 34 NX series Position Interface Units User s Manual W524...
Страница 70: ...2 Specifications and Application Procedures 2 14 NX series Position Interface Units User s Manual W524...
Страница 78: ...3 Part Names and Functions 3 8 NX series Position Interface Units User s Manual W524...
Страница 108: ...4 Installation and Wiring 4 30 NX series Position Interface Units User s Manual W524 Unit...
Страница 114: ...4 Installation and Wiring 4 36 NX series Position Interface Units User s Manual W524...
Страница 126: ...5 I O Refreshing Methods 5 12 NX series Position Interface Units User s Manual W524...
Страница 340: ...8 Pulse Output Units 8 76 NX series Position Interface Units User s Manual W524...
Страница 462: ...Appendices A 74 NX series Position Interface Units User s Manual W524...
Страница 463: ...I 1 I NX series Position Interface Units User s Manual W524 Index...
Страница 466: ...I 4 NX series Position Interface Units User s Manual W524 Index...