![Omron NX-EC0112 Скачать руководство пользователя страница 425](http://html1.mh-extra.com/html/omron/nx-ec0112/nx-ec0112_user-manual_742777425.webp)
A - 37
Appendices
NX-series Position Interface Units User’s Manual (W524)
A-
2 Ob
ject
List
s
A
A-
2-2 Increme
nt
al E
n
coder
Input U
nit
s
• The following table shows the bit configuration of the Pulse Period Measurement object.
• Set this object to the counter type.
• The following table shows the settings for the Counter Type object.
Index
(hex)
Subin-
dex
(hex)
Object name
Default
Data range
Unit
Data type Access
I/O
allo-
cat-
ion
Data
attri-
bute
7008
---
Pulse Period Measure-
ment Function
---
---
---
---
---
---
---
00
Number of Entries
*1
*1. The values for the NX-EC0112, NX-EC0122, NX-EC0132, or NX-EC0142 are 1. The values for the NX-EC0212 or
NX-EC0222 are 2.
*1
---
USINT
RO
No
---
01
Ch1 Pulse Period Mea-
surement Function
0000 hex
0000 to 0007
hex
---
WORD
RW
Yes
N
02
Ch2 Pulse Period Mea-
surement Function
*2
*2. This object does not exist on the NX-EC0112, NX-EC0122, NX-EC0132, and NX-EC0142.
0000 hex
0000 to 0007
hex
---
WORD
RW
Yes
N
Bit
Data name
Description
0
Pulse Period Measurement Enable
*1
*1. If the Edge Detection Method parameter is set to 0, the function is disabled regardless of the status of this
bit.
1: Pulse period measurement enabled.
0: Pulse period measurement disabled.
1
Pulse Period Measurement Value Clear
*2
*2. This can be performed only when pulse period measurement is enabled.
0 to 1: Pulse period measured value and pulse period
measurement counter are cleared.
2
Pulse Period Measurement Value Over-
flow Flag Clear
*2
0 to 1: Pulse period measurement value overflow flag is
cleared.
Other Objects
Index
(hex)
Subin-
dex
(hex)
Object name
Default
Data range
Unit
Data type Access
I/O
allo-
cat-
ion
Data
attri-
bute
5000
---
Counter Type
---
---
---
---
---
---
---
00
Number of Entries
*1
*1. The values for the NX-EC0112, NX-EC0122, NX-EC0132, or NX-EC0142 are 1. The values for the NX-EC0212 or
NX-EC0222 are 2.
*1
---
USINT
RO
No
---
01
Ch1 Counter Type
0
0 or 1
---
USINT
RW
No
Y
02
Ch2 Counter Type
*2
*2. This object does not exist on the NX-EC0112, NX-EC0122, NX-EC0132, and NX-EC0142.
0
0 or 1
---
USINT
RW
No
Y
Set value
Description
0
Ring counter
1
Linear counter
Содержание NX-EC0112
Страница 13: ...11 Manual Structure NX series Position Interface Units User s Manual W524...
Страница 34: ...Revision History 32 NX series Position Interface Units User s Manual W524...
Страница 36: ...Sections in this Manual 34 NX series Position Interface Units User s Manual W524...
Страница 70: ...2 Specifications and Application Procedures 2 14 NX series Position Interface Units User s Manual W524...
Страница 78: ...3 Part Names and Functions 3 8 NX series Position Interface Units User s Manual W524...
Страница 108: ...4 Installation and Wiring 4 30 NX series Position Interface Units User s Manual W524 Unit...
Страница 114: ...4 Installation and Wiring 4 36 NX series Position Interface Units User s Manual W524...
Страница 126: ...5 I O Refreshing Methods 5 12 NX series Position Interface Units User s Manual W524...
Страница 340: ...8 Pulse Output Units 8 76 NX series Position Interface Units User s Manual W524...
Страница 462: ...Appendices A 74 NX series Position Interface Units User s Manual W524...
Страница 463: ...I 1 I NX series Position Interface Units User s Manual W524 Index...
Страница 466: ...I 4 NX series Position Interface Units User s Manual W524 Index...