![Omron NX-EC0112 Скачать руководство пользователя страница 231](http://html1.mh-extra.com/html/omron/nx-ec0112/nx-ec0112_user-manual_742777231.webp)
7 - 25
7 SSI Input Units
NX-series Position Interface Units User’s Manual (W524)
7-6 I/O Refreshin
g Method
Setting
7
7-6
-5 Dif
ferences in I
/O R
efreshi
n
g Methods Base
d on the Con
troller
Set the parameters and assign I/O data for the user program from the Sysmac Studio.
Assign the I/O data in the NJ/NX-series Controller as device variables for the Unit.
Refer to the
NJ/NX-series CPU Unit Software User’s Manual
(Cat. No. W501) for details.
The following table lists the usage restrictions for functions based on their combination with the Ether-
CAT Coupler Unit.
Yes: Usable, No: Not usable
The procedure to set parameters and assign data for the user program depends on the system. Manip-
ulate the Position Interface Unit device parameters through the I/O and message communications pro-
vided by the Controller.
on page A-28 for details.
The following table lists the usage restrictions for functions based on their combination with the Com-
munications Coupler Unit.
Yes: Usable, No: Not usable
Using an NJ/NX-series Controller without the MC Function Module
Function
EtherCAT Coupler Unit
Free-Run refreshing
Synchronous I/O
refreshing
Task period priori-
tized refreshing
*1
*1. Unit version 1.2 or later and an NX-ECC203 EtherCAT Coupler Unit are required.
SSI data settings
Yes
Yes
Yes
Coding method
Yes
Yes
Yes
Encoder count direction
Yes
Yes
Yes
Bit shifting
Yes
Yes
Yes
Parity check
Yes
Yes
Yes
Data refresh status
Yes
Yes
Yes
Error data detection
Yes
Yes
Yes
I/O refreshing method setting
*2
*2. This setting determines the I/O refreshing method.
Yes
Yes
Yes
Time stamping
*3
*3. An EtherCAT Coupler Unit with unit version 1.1 or later is required.
---
Yes
Yes
Other Controllers
Function
EtherCAT Coupler Unit
EtherNet/IP
Coupler Unit
Free-Run
refreshing
Synchronous
I/O refreshing
Task period pri-
oritized refresh-
ing
*1
*1. Unit version 1.2 or later and an NX-ECC203 EtherCAT Coupler Unit are required.
Free-Run
refreshing
SSI data settings
Yes
Yes
Yes
Yes
Coding method
Yes
Yes
Yes
Yes
Encoder count direction
Yes
Yes
Yes
Yes
Bit shifting
Yes
Yes
Yes
Yes
Parity check
Yes
Yes
Yes
Yes
Data refresh status
Yes
Yes
Yes
Yes
Error data detection
Yes
Yes
Yes
Yes
I/O refreshing method setting
Yes
Yes
Yes
No
Time stamping
*2
*2. An EtherCAT Coupler Unit with unit version 1.1 or later is required.
No
Yes
Yes
No
Содержание NX-EC0112
Страница 13: ...11 Manual Structure NX series Position Interface Units User s Manual W524...
Страница 34: ...Revision History 32 NX series Position Interface Units User s Manual W524...
Страница 36: ...Sections in this Manual 34 NX series Position Interface Units User s Manual W524...
Страница 70: ...2 Specifications and Application Procedures 2 14 NX series Position Interface Units User s Manual W524...
Страница 78: ...3 Part Names and Functions 3 8 NX series Position Interface Units User s Manual W524...
Страница 108: ...4 Installation and Wiring 4 30 NX series Position Interface Units User s Manual W524 Unit...
Страница 114: ...4 Installation and Wiring 4 36 NX series Position Interface Units User s Manual W524...
Страница 126: ...5 I O Refreshing Methods 5 12 NX series Position Interface Units User s Manual W524...
Страница 340: ...8 Pulse Output Units 8 76 NX series Position Interface Units User s Manual W524...
Страница 462: ...Appendices A 74 NX series Position Interface Units User s Manual W524...
Страница 463: ...I 1 I NX series Position Interface Units User s Manual W524 Index...
Страница 466: ...I 4 NX series Position Interface Units User s Manual W524 Index...