59
Communicating with the PC Using C200H Direct Communication
Section 2-7
2-7-2
Connection Method
Connect the NT20S and PC.
The connection conditions are different for C200H/HS, C200HX/HG/HE and
C
jj
H.
Caution:
S
Always turn off the power at the PC and PT before connecting the C200H inter-
face cable. Otherwise the system may operate unpredictably.
S
After connecting the communication cable, always secure it with the screws.
Otherwise the cable may disconnect, causing operation to fail.
[I/O connection cable]
Use the following models of I/O connection cable.
Model
Cable Length (L)
C200H-CN311
30 cm
NT20M-CNP711
C200H-CN711
70 cm
For connecting
C200H/HS/HE/HG/HX
NT20M-CNP221
C200H-CN221
2 m
C200H/HS/HE/HG/HX
NT20M-CNP521
C200H-CN521
5 m
NT20M-CNP131
C200H-CN131
10 m
C20H-CN312
30 cm
For connecting C
jj
H
NT20M-CNP712
C20H-CN712
70 cm
For connecting C
jj
H
NT20M-CNP222
C20H-CN222
2 m
The C200H interface side connector of NT20M-CNP
jjj
has been down-
sized.
Caution:
S
Keep the total length of I/O cables used within 12 m (6 m for C
jj
H).
S
The cable’s tensile load is 30 N. Do not subject it to loads greater than this.
Otherwise a discontinuity may occur, causing operation to fail.
Reference: If a C200H-CN
jjj
or C20H-CN
jjj
is used as the I/O connection cable, the
connector will project beyond the bottom face of the NT20S.
If the I/O cable is passed through a hole or other opening, the hole or opening must
be at least 53 mm
φ
. Removing the top cover reduces this requirement to 33 mm
φ
or larger. During installation, this cover must be replaced before securing the PT.
Содержание NT20S
Страница 1: ...Cat No V020 E1 04 NT20S Programmable Terminal OPERATION MANUAL ...
Страница 2: ...i ...
Страница 3: ...ii ...
Страница 4: ...iii NT series Programmable Terminal Operation Manual Revised August 1997 ...
Страница 5: ...iv ...
Страница 7: ...vi ...
Страница 11: ...x ...
Страница 19: ...xviii ...
Страница 129: ...110 ...
Страница 169: ...150 ...
Страница 253: ...234 ...