To remove the NT2000M from the panel, use a Phillips screwdriver.
Phillips screwdriver
View from rear
É
É
É
A
A
A
A
2-5
Wiring and Connectors
2-5-1
Terminal Block
The terminal blocks illustrated below are located under the respective termi-
nal block covers of the NT20M and the NT2000M.
NT20M
10
10
1.4
3
ALM
OUTPUT
HOST
RUN
INPUT
24 VDC
Terminal screws: M3.5
+
Dimensions are in millimeters.
NT2000M
HOST
RUN
INPUT
ALARM
OUTPUT
LG
GR
100 to 240 VAC
50/60 Hz
Terminal screws: M4
Crimp-style Terminals for Wiring
Use crimp-style terminals for wiring. If twisted wires are connected directly,
there is a possibility of poor contact or short-circuiting. For the NT20M, use
crimp-style terminals with holes to match M3.5 screws. For the NT2000M,
use crimp-style terminals with holes to match M4 screws. The dimensions
shown in the illustration below are for the NT20M. For the NT2000M, the di-
mensions would be 8.6 mm max. for both the fork-type and the round-type.
7 mm max.
Fork-type
8 mm max.
Round-type
Wiring and Connectors
Section 2-5