MicroHAWK Engine Integration Guide
15-7
Output Format
Format Insert
Output Index
Length
Hex String
Definition:
Output Index
refers to the database entry you wish to modify with this command.
A formatted output is built by extracting data from a symbol’s original data
output and/or
inserting user-defined characters
.
It may be helpful to think of individual indexes as positions in the final formatted
output you wish to build. Starting with index # 1, enter either an extract or
insert command to begin building your desired output string. Then, with the
next index number, enter either an extract or insert command to continue
building the output string. Continue this process until you are finished building
the string.
Serial Cmd:
<
K741,
output index
,length,hex string>
Options:
1 to 100
Definition:
Specifies the length of the user-defined character string that will be inserted.
This function is limited to 4 characters per output index, so multiple indexes
must be entered in order to insert longer character sequences.
For example, if you wish to insert a 10 character sequence in user-defined
output, you would need three commands with consecutive index numbers,
where the first two character sequence lengths were 4 and the third was 2.
Serial Cmd:
<
K741,
output index,
length
,hex string>
Default:
0
(disabled; end of format cell array)
Options:
1 to 4
Definition:
Specifies a character string that represents ASCII characters to be inserted in
the database entry. Two hex characters are required for every ASCII character
to be inserted in the user-defined output string. These two characters comprise
the hex (base 16) value of the ASCII character.
For example, if you wanted to enter the three-character sequence “Hi!” you
would enter
3
for the length of the string, and a hex sequence of
486921
for
the ASCII sequence to be inserted. (48 = H; 69 = i; 21 = !)
Important:
Each pair of hex characters represents one ASCII character. Hex
character pairs range from 00 to FF. Since you are limited to 4 ASCII characters
per insertion per database entry, you are likewise limited to 8 hex characters
per insertion per database entry.
Serial Cmd:
<
K741,
output index,length,
hex string
>
Default:
NUL
(00 in hex)
Options:
00 to FF (As many as 4 bytes, or hex values.)
Содержание MicroHAWK
Страница 1: ...MicroHAWK Engine Integration Guide P N 84 9007100 02 Rev B...
Страница 74: ...2 18 MicroHAWK Engine Integration Guide Send Receive Options...
Страница 78: ...3 4 MicroHAWK Engine Integration Guide Optical Requirements Optical Requirements Base Side...
Страница 79: ...MicroHAWK Engine Integration Guide 3 5 Integration Viewing Port Specifications...
Страница 80: ...3 6 MicroHAWK Engine Integration Guide Expansion Connector FPC Expansion Connector FPC...
Страница 101: ...MicroHAWK Engine Integration Guide 4 21 Communications Keyboard Languages...
Страница 102: ...4 22 MicroHAWK Engine Integration Guide USB HID Keyboard Keyboard Languages continued...
Страница 103: ...MicroHAWK Engine Integration Guide 4 23 Communications Keyboard Languages continued...
Страница 108: ...4 28 MicroHAWK Engine Integration Guide Entering ASCII Characters as Hex Values...
Страница 120: ...5 12 MicroHAWK Engine Integration Guide Additional Notes about Calibration...
Страница 148: ...6 28 MicroHAWK Engine Integration Guide Minimum Good Reads...
Страница 188: ...7 40 MicroHAWK Engine Integration Guide DotCode...
Страница 238: ...8 50 MicroHAWK Engine Integration Guide Image Push to Host Detailed Setup...
Страница 268: ...10 14 MicroHAWK Engine Integration Guide New Master Pin...
Страница 296: ...11 28 MicroHAWK Engine Integration Guide Set License...
Страница 314: ...12 18 MicroHAWK Engine Integration Guide Request All Configuration Database Settings...