[1] Setup of Language
Set the language used for the display.
[2] Communication Protocol [Compoway/F, Modbus]
Set the protocol used for the communication.
If you set "Auto", the protocol of the received communication data is distinguished and it communicates by
Compoway/F or Modbus.
After set the protocol, disconnect the solar modules (turn-off the switch in DC side) and connect again to confirm
the value.
[3] Communication Unit Number [Compoway/F, Modbus]
Set the unit number used for the communication.
After set the unit number, disconnect the solar modules (turn-off the switch in DC side) and connect again to
confirm the value.
[4] Communication Baud rate(RS-232C) [Compoway/F]
Set the transfer rate of the communication of RS-232C.
After set the baud rate, disconnect the solar modules (turn-off the switch in DC side) and connect again to
confirm the value.
[5] Communication Baud rate(RS-485) [Compoway/F, Modbus]
Set the transfer rate of the communication of RS-485.
After set the baud rate, disconnect the solar modules (turn-off the switch in DC side) and connect again to
confirm the value.
[6] Communication Parity [Modbus only]
Set the parity for the communication.
After set the parity, disconnect the solar modules (turn-off the switch in DC side) and connect again to confirm the
value.
[7] Communication Stop bit [Modbus only]
Set the stop bit for the communication.
After set the stop bit, disconnect the solar modules (turn-off the switch in DC side) and connect again to confirm
the value.
[8] RS-485 Communication Send wait the time [Compoway/F, Modbus]
Set the wait time from receiving of the RS-485 command to sending the RS-485 command.
Adjust the RS-485 Communication Send wait time of the KP100L according to the switch time of the RS-485
transmission enable of the host side.
After set the wait time, disconnect the solar modules (turn-off the switch in DC side) and connect again to confirm
the value.
[9] Change of parameter level (GER or ITA)
Change the specific detect level. The detect level that you can change is different according to the country
setting.
Refer to " 3-6" for detail.
Содержание KP100L-OD - 12-2010
Страница 18: ...17 Grid Connect Photovoltaic Inverte KP100L OD USER S MANUAL ...
Страница 21: ...20 Grid Connect Photovoltaic Inverte KP100L OD USER S MANUAL ...
Страница 33: ...1 Overview 1 12 Grid Connect Photovoltaic Inverte KP100L OD USER S MANUAL ...
Страница 63: ...2 Design 2 30 Grid Connect Photovoltaic Inverte KP100L OD USER S MANUAL ...
Страница 103: ...4 Maintenance Operations 4 12 Grid Connect Photovoltaic Inverter KP100L OD USER S MANUAL ...
Страница 113: ...6 After Sales Service 6 4 Grid Connect Photovoltaic Inverter KP100L OD USER S MANUAL ...
Страница 114: ...7 1 7 7 Grid Connect Photovoltaic Inverter KP100L OD USER S MANUAL 7 1 Standard Specification List 7 2 Specifications ...
Страница 117: ...7 Specifications 7 4 Grid Connect Photovoltaic Inverter KP100L OD USER S MANUAL ...
Страница 125: ...A Appendix A 8 Grid Connect Photovoltaic Inverter KP100L OD USER S MANUAL ...