2 Design
2 - 14
Grid Connect Photovoltaic Inverte KP100L-OD-
USER’S MANUAL
Connecting the Communication Cable
Wiring for the communications cable to the KP100L as follow steps
(1) Remove the cap of communications cable clamp, and take the rubber bush out.
(2) Puncture only the necessary parts of the rubber bush taken out with a tool like gimlet, and pass wiring.
Use the cable and the wire in the table below.
Two spare rubber bush are bundled. Use bundled rubber bush when you make a mistake in the
punctured processing.
(3) Pass the communication cable through the hole of the product. Set the rubber bush in the main body of
the cable clamp, and tighten the cap lightly.
Diameter of cable
4.0mm
Diameter of wire
solid wire /
0.4-1.2 (AWG26-16)
Length in which the insulating coating of the
cable is peeled off and taken
Cap
Rubber Bush
Cap
Rubber Bush
7mm
Tighten the cap lightly
Содержание KP100L-OD - 12-2010
Страница 18: ...17 Grid Connect Photovoltaic Inverte KP100L OD USER S MANUAL ...
Страница 21: ...20 Grid Connect Photovoltaic Inverte KP100L OD USER S MANUAL ...
Страница 33: ...1 Overview 1 12 Grid Connect Photovoltaic Inverte KP100L OD USER S MANUAL ...
Страница 63: ...2 Design 2 30 Grid Connect Photovoltaic Inverte KP100L OD USER S MANUAL ...
Страница 103: ...4 Maintenance Operations 4 12 Grid Connect Photovoltaic Inverter KP100L OD USER S MANUAL ...
Страница 113: ...6 After Sales Service 6 4 Grid Connect Photovoltaic Inverter KP100L OD USER S MANUAL ...
Страница 114: ...7 1 7 7 Grid Connect Photovoltaic Inverter KP100L OD USER S MANUAL 7 1 Standard Specification List 7 2 Specifications ...
Страница 117: ...7 Specifications 7 4 Grid Connect Photovoltaic Inverter KP100L OD USER S MANUAL ...
Страница 125: ...A Appendix A 8 Grid Connect Photovoltaic Inverter KP100L OD USER S MANUAL ...