3-23
3-6 Parameter List
3
Operation
Electron
ic therma
l
b013
Electronic thermal
characteristics
selection
00: Reduced torque characteristics 1
01: Constant torque characteristics
02: Reduced torque characteristics 2
00
No
⎯
10AE
4-32
b213
*2nd electronic
thermal
characteristics
selection
00
1528
Over
load
limit
b021
Overload limit
selection
00: Disabled
01: Enabled in acceleration/constant speed
operation
02: Enabled in constant speed operation
01
No
⎯
10B5
4-33
b221
*2nd overload limit
selection
01
1529
b022
Overload limit level
0..1 × Rated current to 1.5 × Rated current
1.5 ×
Rated
current
No
A
10B6
4-33
b222
*2nd overload limit
level
1.5 ×
Rated
current
152A
b023
Overload limit
parameter
0.1 to 3000.0
1.0
No
s
10B7
4-33
b223
*2nd overload limit
parameter
1.0
152B
b028
Overload limit source
selection
00: b022, b222 set values
01: Input terminal O
00
No
⎯
10BB
4-33
b228
*2nd overload limit
source selection
00
152C
Active Freq Match
b029
Deceleration rate
constant at Active
Frequency Matching
restart
0.1 to 3000.0
0.5
No
s
1171
4-30
b030
Active Frequency
Matching restart level
0.2 × Rated current to 2.0 × Rated current
Rated
current
No
A
1172
4-30
Lock
b031
Soft lock selection
00: Data other than b031 cannot be changed
when terminal SFT is ON.
01: Data other than b031 and the specified
frequency parameter cannot be changed when
terminal SFT is ON.
02: Data other than b031 cannot be changed.
03: Data other than b031 and the specified
frequency parameter cannot be changed.
10: Data other than parameters changeable
during operation cannot be changed.
01
No
⎯
10BC
4-35
Non-stop at
momentary powe
r interr
uption
b050
Selection of non-stop
function at
momentary power
interruption
00: Disabled
01: Enabled (Stop)
02: Enabled (Restart)
00
No
10C9
4-36
b051
Starting voltage of
non-stop function at
momentary power
interruption
0.0 to 1000.
0.0
No
V
10CA
4-36
b052
Stop deceleration
level of non-stop
function at
momentary power
interruption
0.0 to 1000.
0.0
No
V
10CB
4-36
Parameter
No.
Function name
Monitor or data range
(Digital Operator)
Default
setting
Change
during
Run
Unit
Modbus
Address
(Hex)
Page
Содержание JX-A4004
Страница 2: ......
Страница 16: ...14 About This Manual ...
Страница 19: ...Chapter 1 Overview 1 1 Functions 1 2 1 2 Appearance and Names of Parts 1 4 ...
Страница 24: ......
Страница 25: ...Chapter 2 Design 2 1 Installation 2 2 2 2 Wiring 2 7 ...
Страница 79: ...Chapter 4 Functions 4 1 Monitor Mode 4 2 4 2 Function Mode 4 6 ...
Страница 167: ...Chapter 5 Maintenance Operations 5 1 Special Display List Error Codes 5 2 5 2 Troubleshooting 5 6 ...
Страница 174: ...5 8 5 2 Troubleshooting 5 Maintenance Operations ...
Страница 175: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 2 6 2 Storage 6 8 ...
Страница 190: ...7 8 7 3 Dimensional Drawing 7 Specifications JX A2004 AB004 80 5 6 143 1 9 109 5 27 2 6 107 155 67 5 ...
Страница 191: ...7 9 7 3 Dimensional Drawing 7 Specifications JX A2007 80 67 5 5 6 143 1 9 132 5 50 2 6 130 155 ...
Страница 192: ...7 10 7 3 Dimensional Drawing 7 Specifications JX A4004 AB007 110 98 5 5 6 176 189 128 1 9 130 5 28 2 6 ...
Страница 194: ...7 12 7 3 Dimensional Drawing 7 Specifications JX A2055 A2075 A4055 A4075 180 235 165 250 164 6 1 9 167 5 90 1 6 ...
Страница 199: ...Appendix Appendix 1Parameter ListApp 2 Appendix 2Product Life CurveApp 18 ...
Страница 217: ...INDEX ...
Страница 220: ......