2-21
2-2 Wiring
2
De
sign
Specifications of the Control Circuit Terminals
Terminal
symbol
Terminal name and function
Default setting
Specifications
Input signal
PCS
External power supply terminal for input
signal (input).......................At sink logic
Internal power supply output terminal for
input signal (output)......At source logic
⎯
24 V DC ±10%
30 mA max.
24 V DC ±10%
100 mA max.
1
Multi-function input terminals 1 to 5
Select 5 functions among the 31
functions and allocate them to from
terminals 1 to 5.
The terminal allocation is changed
automatically when the emergency
shutoff function is used. Refer to
"Emergency Shutoff Input Function"
(page 4-46).
Forward/Stop
Contact input
Close: ON (Start)
Open: OFF (Stop)
Minimum ON time:
12 ms min.
2
Reverse/Stop
3
Fault reset
4
Emergency stop
fault
5
Multi-step speed
reference 1
L
Input signal common
⎯
Monitor
signal
AM
Analog frequency monitor/
Analog output current monitor
Analog
frequency
monitor
Frequency
reference
input
H
Frequency reference power supply
⎯
10 V DC
10 mA max.
O
Voltage frequency reference signal
⎯
0 to 10 V DC
Input impedance 10 k
Ω
When installing variable
resistors at FS, FV, and FC
(1 to 2 k
Ω
)
OI
Current frequency reference signal
⎯
4 to 20 mA DC
Input impedance 250
Ω
L
Frequency reference common
⎯
Output signal
11
Multi-function output terminal
Select the status of the Inverter and
allocate it to terminal P1.
Frequency
arrival signal at
a constant
speed
27 V DC
50 mA max.
CM2
Output signal common
⎯
Relay output
signal
AL2
Under normal operation : AL2-AL0 Closed
Under abnormal operation or power
shutdown
: AL1-AL0 Open
(Default)
Contact ratings
250 V AC 2.0 A (resistance load) 100 V AC min.
0.2 A (inductive load) 10 mA
30 V DC
3.0 A (resistance load) 5 V DC
0.6 A (inductive load) 100 mA
AL1
AL0
AL1
AL2
AL0
Содержание JX-A4004
Страница 2: ......
Страница 16: ...14 About This Manual ...
Страница 19: ...Chapter 1 Overview 1 1 Functions 1 2 1 2 Appearance and Names of Parts 1 4 ...
Страница 24: ......
Страница 25: ...Chapter 2 Design 2 1 Installation 2 2 2 2 Wiring 2 7 ...
Страница 79: ...Chapter 4 Functions 4 1 Monitor Mode 4 2 4 2 Function Mode 4 6 ...
Страница 167: ...Chapter 5 Maintenance Operations 5 1 Special Display List Error Codes 5 2 5 2 Troubleshooting 5 6 ...
Страница 174: ...5 8 5 2 Troubleshooting 5 Maintenance Operations ...
Страница 175: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 2 6 2 Storage 6 8 ...
Страница 190: ...7 8 7 3 Dimensional Drawing 7 Specifications JX A2004 AB004 80 5 6 143 1 9 109 5 27 2 6 107 155 67 5 ...
Страница 191: ...7 9 7 3 Dimensional Drawing 7 Specifications JX A2007 80 67 5 5 6 143 1 9 132 5 50 2 6 130 155 ...
Страница 192: ...7 10 7 3 Dimensional Drawing 7 Specifications JX A4004 AB007 110 98 5 5 6 176 189 128 1 9 130 5 28 2 6 ...
Страница 194: ...7 12 7 3 Dimensional Drawing 7 Specifications JX A2055 A2075 A4055 A4075 180 235 165 250 164 6 1 9 167 5 90 1 6 ...
Страница 199: ...Appendix Appendix 1Parameter ListApp 2 Appendix 2Product Life CurveApp 18 ...
Страница 217: ...INDEX ...
Страница 220: ......