18.  Technical Data

Product Description

OMRON Body Composition Monitor

Model

HBF-255T

Display*

1

Body Weight:

2.0 to 100.0 kg with an increment of 0.05 kg 
100 to 135 kg with an increment of 0.1 kg

Body Fat percentage:

5.0 to 50.0% with an increment of 0.1%

Skeletal Muscle 
percentage:

5.0 to 60.0% with an increment of 0.1%

BMI:

2.5 to 90.0 with an increment of 0.1

Resting Metabolism:

385 to 3999 kcal with an increment of 1 kcal

Body Age:

18 to 80 years old with an increment of 1 year

Visceral Fat Level:

30 levels with an increment of 1 level

Body fat percentage, Skeletal muscle percentage classification:

– (Low) / 0 (Normal) / + (High) / ++ (Very High) 4 levels with 3 sublevels each

Visceral fat level classification:

0 (Normal) / + (High) / ++ (Very High) 3 levels with 3 sublevels each

*

1

 The age range for the Body Fat percentage, Body fat percentage classification, Skeletal Muscle 

percentage, Skeletal Muscle percentage classification, Resting Metabolism is Over 6 years old.

*

1

 The age range for the Visceral Fat level, Visceral Fat level classification and Body Age is Over 18 

years old.

Transmission Protocol

Bluetooth

®

 

low energy technology

Wireless communication Frequency range:

 

Modulation:

 

Effective radiated power:

 

2.4 GHz (2400 - 2483.5 MHz)
GFSK
<20 dBm

Setting Items*

2

The following information can be stored for up to 4 persons.

Measurement unit

kg&cm

Birth date

January 1st, 1900 to December 31st, 2045

Gender

Male / Female

Height

100.0 to 199.5 cm with an increment of 0.5 cm 

*

2

 When the height of a person is less than 100.0 cm or more than 199.5 cm, BMI and body 

composition measurement results are for reference.

Weight Accuracy

2.0 kg to 40.0 kg: ± 0.4 kg

40.0 kg to 135.0 kg: ± 1%

Accuracy (S.E.E.*

3

)

Body Fat percentage:

3.5%

Skeletal Muscle percentage: 

3.5%

Visceral Fat Level: 

3 levels

Durable Period

5 years

Power Supply

4 AAA alkaline batteries (LR03)

Battery Life

Approximately 6 months (When AAA alkaline batteries are used in four measurements, two data 
transfers in BLE and two data transfers in manual BLE per day at a room temperature of 23°C)

Operating Temperature/
Humidity/Air Pressure

+5°C to +40°C, 30% to 85% RH (no-condensing), 860 hPa to 1060 hPa

Storage and Transport 
Temperature/Humidity/
Air Pressure

-20°C to +60°C, 10% to 95% RH (no-condensing), 860 hPa to 1060 hPa

Weight

Approx. 1.7 kg (including batteries)

External Dimensions

Approx. 327(W) x 30(H) x 249(D) mm

Contents

Body composition monitor, 4 AAA alkaline batteries (LR03), 
Setup Instructions, Instruction Manual, Caution Sheet, Quick Start Guide

*

3

 S.E.E: standard error of estimation

Note

*Below 6 years old: Only Body weight and BMI can be measured.

Below 18 years old: Visceral fat level and body age cannot be measured.
Over 81 years old: Body composition is for reference value.

•  Subject to technical modification without prior notice.

Содержание HBF-255T

Страница 1: ...ing the OMRON Body Composition Monitor Before using this unit please be sure to read this Instruction Manual carefully to understand the safe and proper use Please store this Instruction Manual carefu...

Страница 2: ...Your Smart Device 6 4 Set the Date and Time 7 5 Register the Personal Data 8 Operating instructions 9 6 How to Take a Measurement Accurately 9 6 1 Correct postures during the measurement 9 6 2 About t...

Страница 3: ...quencies RF in the 2 4 GHz band Do not use this product in locations where RF is restricted such as on an aircraft or in hospitals As this unit is a precision instrument do not drop vibrate or apply s...

Страница 4: ...your measurement result is being transferred to your smart device This may result in the incorrect operation of your unit and failure to transfer your measurement result Incorrect Measurement Incorre...

Страница 5: ...personal data Transmission Button Press this button to pair the unit with your smart device OFF Button Press this button to turn off the power Display Battery Symbol low depleted Weight Symbol Lights...

Страница 6: ...use manganese dry batteries or rechargeable batteries due to very short use times become the cause of wrong operation Replace all four batteries with new ones same type at the same time When the low...

Страница 7: ...address www omronconnect com setup code image Search the OMRON connect app from App Store or Google Play 3 Open the app on your smart device and follow set up and pairing instructions If you already h...

Страница 8: ...the correct date and time Touch the and button to adjust and touch the button to confirm Time is 24 hour system After all the settings for the year month day hour and minute are displayed in that seq...

Страница 9: ...2045 4 Set the gender Touch the and button to set the gender MALE or FEMALE and touch the button to confirm 5 Set the height Touch the and button to adjust the height and touch the button to confirm A...

Страница 10: ...placed on the unit nit is leaning against the r other objects The unit is placed upside down The unit is placed on an object An object is placed on the unit The unit is leaning against the wall or oth...

Страница 11: ...ted Step off the unit 3 Confirm your personal number If your personal number is correct Touch the button to confirm your personal number If your personal number is incorrect Before the power turns off...

Страница 12: ...e and BMI classification indicator as a guide to measurement To better understand your measurement results refer to the information and diagrams in Section 19 and 20 WEIGHT BODY AGE BMI RESTING METABO...

Страница 13: ...the measurement result you want to view Note When the measurement result exceeds 30 times it is deleted from the older measurement result in turn Operating instructions 9 View the Measurement Results...

Страница 14: ...rsonal number 1 blinks 2 Select your personal number Select your personal number with the and button 3 Touch the button to confirm your personal number 0 00 kg is displayed 4 Take a measurement when 0...

Страница 15: ...3 no 4 GUEST no no 0 no 1 appear in sequence on the display 3 Touch the button to confirm the personal number 0 00 kg is displayed 4 Enter personal data 4 1 Set the birth date Touch the and button to...

Страница 16: ...uch the button to turn on the power The power turns on Personal number 1 blinks 2 Select no 0 with the and button Every time you touch the button no 1 no 2 no 3 no 4 GUEST no no 0 no 1 are displayed i...

Страница 17: ...Touch Button Back Touch Button 1 Touch the button to turn on the power The power turns on Personal number 1 blinks 2 Touch and button to select no 0 Every time you touch the button no 1 no 2 no 3 no...

Страница 18: ...result is displayed 8 When the measurement result is displayed step down from the unit The 1st and 2nd body weight difference is displayed after the 2nd measurement result is displayed When the body w...

Страница 19: ...using the personal number which has been used by another person delete the personal data and then register the personal data again Change your personal data The measurement results will not be deleted...

Страница 20: ...soft dry cloth If necessary use a cloth moistened with water or detergent and squeeze it well before wiping the unit then wipe off with a dry cloth Do not use benzene or thinner or other volatile sol...

Страница 21: ...h a wet towel and try again Abnormal operation Remove and then re insert the battery Once this is complete please restart the device If this error continues to display consult the OMRON service repres...

Страница 22: ...e settings of birth date gender and height are correct Even if these settings are correct is displayed if they are out of the displayable or supported age range The measurement result is higher or low...

Страница 23: ...on can be stored for up to 4 persons Measurement unit kg cm Birth date January 1st 1900 to December 31st 2045 Gender Male Female Height 100 0 to 199 5 cm with an increment of 0 5 cm 2 When the height...

Страница 24: ...ody composition 19 Information on Body Composition Principle of body composition calculation Body fat has low electric conductivity HBF 255T measures the body fat percentage by the Bioelectrical Imped...

Страница 25: ...fat levels to an acceptable level People with high visceral fat levels tend to have large stomachs However this is not always the case and high visceral fat levels can lead to metabolic obesity Metabo...

Страница 26: ...13 3 16 5 23 3 26 5 5 16 6 19 9 26 6 29 9 6 20 0 21 6 30 0 31 6 High 7 21 7 23 3 31 7 33 3 8 23 4 24 9 33 4 34 9 9 25 0 33 3 35 0 39 9 Very High 10 33 4 41 7 40 0 44 9 11 41 8 50 0 45 0 50 0 12 Based...

Страница 27: ...Female Resting Metabolism Base Value kcal kg Body Weight Day Reference Body Weight kg Resting Metabolism kcal Day Resting Metabolism Base Value kcal kg Body Weight Day Reference Body Weight kg Resting...

Страница 28: ...PRODUCTION FACILITY KRELL PRECISION YANGZHOU CO LTD No 28 Xingyang Road Economic Development ZoneYangzhou Jiangsu 225009 China Asia Pacific HQ OMRON HEALTHCARE SINGAPORE PTE LTD 438A Alexandra Road 0...

Отзывы: