manualshive.com logo in svg
background image

23

This Product operates in the unlicensed ISM band at 2.4GHz. In case this Product is used around the other 
wireless devices including microwave and wireless LAN, which operate same frequency band of this Product, 
there is a possibility that interference occurs between this Product and such other devices. If such interference 
occurs, please stop the operation of other devices or relocate this Product before using this Product or do not use 
this Product around the other wireless devices. 

The 

Bluetooth

®

 word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use 

of such marks by OMRON HEALTHCARE Co., Ltd. is under license.

Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries.  
App Store is a service mark of Apple Inc.  
Android, the Google Play logo are trademarks of Google Inc.

Description of symbols that, depending on a model, can be found on the product itself, product sales package or IM.

Direct current

Serial number

This product should not be used by persons with 

medical implants, e.g. heart pacemakers, artificial 

heart, lung or other electronic life support systems.

Temperature limitation

Atmospheric pressure limitation

Humidity limitation

Need for the user to consult the instructions for use

Product production date is integrated in a Serial number, which is placed on the sales package: the first 4 digits mean year of 

production, the next 2 digits - month of production.

Information on body composition

19.   Information on Body Composition

Principle of body composition calculation

Body fat has low electric conductivity

HBF-255T measures the body fat percentage by the Bioelectrical Impedance (BI) method. Muscles, blood vessels and bones are 
body tissues with a high water content that conducts electricity easily. Body fat is tissue that has little electric conductivity. The 
unit sends an extremely weak electrical current of 50 kHz and less than 500 µA through your body to determine the amount of fat 
tissue. This weak electrical current is not felt while operating the unit.
In order for the scale to determine your body composition, it uses the electrical impedance, along with your height, weight, age 
and gender information to generate results based on OMRON’s data of body composition.

Recommended measurement times

Understanding the normal changes in your body fat percentage can help 
you in preventing or reducing obesity. Being aware of the times when the 
body fat percentages shift within your own daily schedule will assist you 
in obtaining an accurate trending of your body fat. It is recommended 
to use this unit in the same environment and daily circumstances. (See 
chart)

Daily activities

Waking up

Breakfast

Lunch

Taking a bath or 

eating dinner

Going to bed

2 hours

2 hours

2 hours

Recommended time 

Recommended time 

Recommended time 

Recommended time 

Before going to bed and about 2 

hours or more after dinner or bath

Before lunch and about 2 hours 

or more after breakfast

After waking up

In the afternoon about 2 hours 

or more after lunch and before 

taking a bath or eating dinner

Avoid measurement immediately 

after eating or bathing.

Содержание HBF-255T

Страница 1: ...ing the OMRON Body Composition Monitor Before using this unit please be sure to read this Instruction Manual carefully to understand the safe and proper use Please store this Instruction Manual carefu...

Страница 2: ...Your Smart Device 6 4 Set the Date and Time 7 5 Register the Personal Data 8 Operating instructions 9 6 How to Take a Measurement Accurately 9 6 1 Correct postures during the measurement 9 6 2 About t...

Страница 3: ...quencies RF in the 2 4 GHz band Do not use this product in locations where RF is restricted such as on an aircraft or in hospitals As this unit is a precision instrument do not drop vibrate or apply s...

Страница 4: ...your measurement result is being transferred to your smart device This may result in the incorrect operation of your unit and failure to transfer your measurement result Incorrect Measurement Incorre...

Страница 5: ...personal data Transmission Button Press this button to pair the unit with your smart device OFF Button Press this button to turn off the power Display Battery Symbol low depleted Weight Symbol Lights...

Страница 6: ...use manganese dry batteries or rechargeable batteries due to very short use times become the cause of wrong operation Replace all four batteries with new ones same type at the same time When the low...

Страница 7: ...address www omronconnect com setup code image Search the OMRON connect app from App Store or Google Play 3 Open the app on your smart device and follow set up and pairing instructions If you already h...

Страница 8: ...the correct date and time Touch the and button to adjust and touch the button to confirm Time is 24 hour system After all the settings for the year month day hour and minute are displayed in that seq...

Страница 9: ...2045 4 Set the gender Touch the and button to set the gender MALE or FEMALE and touch the button to confirm 5 Set the height Touch the and button to adjust the height and touch the button to confirm A...

Страница 10: ...placed on the unit nit is leaning against the r other objects The unit is placed upside down The unit is placed on an object An object is placed on the unit The unit is leaning against the wall or oth...

Страница 11: ...ted Step off the unit 3 Confirm your personal number If your personal number is correct Touch the button to confirm your personal number If your personal number is incorrect Before the power turns off...

Страница 12: ...e and BMI classification indicator as a guide to measurement To better understand your measurement results refer to the information and diagrams in Section 19 and 20 WEIGHT BODY AGE BMI RESTING METABO...

Страница 13: ...the measurement result you want to view Note When the measurement result exceeds 30 times it is deleted from the older measurement result in turn Operating instructions 9 View the Measurement Results...

Страница 14: ...rsonal number 1 blinks 2 Select your personal number Select your personal number with the and button 3 Touch the button to confirm your personal number 0 00 kg is displayed 4 Take a measurement when 0...

Страница 15: ...3 no 4 GUEST no no 0 no 1 appear in sequence on the display 3 Touch the button to confirm the personal number 0 00 kg is displayed 4 Enter personal data 4 1 Set the birth date Touch the and button to...

Страница 16: ...uch the button to turn on the power The power turns on Personal number 1 blinks 2 Select no 0 with the and button Every time you touch the button no 1 no 2 no 3 no 4 GUEST no no 0 no 1 are displayed i...

Страница 17: ...Touch Button Back Touch Button 1 Touch the button to turn on the power The power turns on Personal number 1 blinks 2 Touch and button to select no 0 Every time you touch the button no 1 no 2 no 3 no...

Страница 18: ...result is displayed 8 When the measurement result is displayed step down from the unit The 1st and 2nd body weight difference is displayed after the 2nd measurement result is displayed When the body w...

Страница 19: ...using the personal number which has been used by another person delete the personal data and then register the personal data again Change your personal data The measurement results will not be deleted...

Страница 20: ...soft dry cloth If necessary use a cloth moistened with water or detergent and squeeze it well before wiping the unit then wipe off with a dry cloth Do not use benzene or thinner or other volatile sol...

Страница 21: ...h a wet towel and try again Abnormal operation Remove and then re insert the battery Once this is complete please restart the device If this error continues to display consult the OMRON service repres...

Страница 22: ...e settings of birth date gender and height are correct Even if these settings are correct is displayed if they are out of the displayable or supported age range The measurement result is higher or low...

Страница 23: ...on can be stored for up to 4 persons Measurement unit kg cm Birth date January 1st 1900 to December 31st 2045 Gender Male Female Height 100 0 to 199 5 cm with an increment of 0 5 cm 2 When the height...

Страница 24: ...ody composition 19 Information on Body Composition Principle of body composition calculation Body fat has low electric conductivity HBF 255T measures the body fat percentage by the Bioelectrical Imped...

Страница 25: ...fat levels to an acceptable level People with high visceral fat levels tend to have large stomachs However this is not always the case and high visceral fat levels can lead to metabolic obesity Metabo...

Страница 26: ...13 3 16 5 23 3 26 5 5 16 6 19 9 26 6 29 9 6 20 0 21 6 30 0 31 6 High 7 21 7 23 3 31 7 33 3 8 23 4 24 9 33 4 34 9 9 25 0 33 3 35 0 39 9 Very High 10 33 4 41 7 40 0 44 9 11 41 8 50 0 45 0 50 0 12 Based...

Страница 27: ...Female Resting Metabolism Base Value kcal kg Body Weight Day Reference Body Weight kg Resting Metabolism kcal Day Resting Metabolism Base Value kcal kg Body Weight Day Reference Body Weight kg Resting...

Страница 28: ...PRODUCTION FACILITY KRELL PRECISION YANGZHOU CO LTD No 28 Xingyang Road Economic Development ZoneYangzhou Jiangsu 225009 China Asia Pacific HQ OMRON HEALTHCARE SINGAPORE PTE LTD 438A Alexandra Road 0...

Отзывы: