Model

HBF-206IT (HBF-206IT-Z)

Display

Body Weight:

 

0 to 330 lb with 0.2 lb increments
(0 to 150 kg with 0.1 kg increments)

Body fat percentage:

 5.0 to 60.0% with 0.1% increments

Skeletal muscle percentage:

 5.0 to 50.0% with 0.1% increments

BMI:

 7.0 to 90.0 with 0.1 increments

Resting metabolism:

 

385 to 3999 kcal with 1 kcal increments

Body age:

 

18 to 80 years old with 1 year increments

Visceral fat level:

 30 levels with 1 level increments

Body fat percentage and Skeletal muscle percentage classification:

– (Low) / 0 (Normal) / + (High) / ++ (Very High) 4 levels with 3 sublevels each

Visceral fat classification:

 

0 (Normal) / + (High) / ++ (Very High) 3 levels with 3 sublevels each

* The age range for the Body Fat Percentage is 10 to 80 years old.
* The age range for the Skeletal Muscle Percentage, Skeletal Muscle 

Percentage Classification, Resting Metabolism rate, Visceral Fat Level, 
Visceral Fat Level Classification and Body age is 18  to 80 years old.

* The age range for the Body Fat Percentage Classification is 20 to 80 years 

old.

Memory

Display memory:

Last (previous) measurement results

Unit stored memory:

Up to 30 sets

Transmission protocol

Bluetooth

®

 wireless technology Version 2.1 + EDR Class 2

Set Ranges

Personal data Information:

The following information for up to 4 people can be stored.

Height:

 

3' 4" to 6' 6 3/4" (100.0 to 199.5 cm)

Birth Date:

 

January 1st, 1900 to December 31st, 2030

Gender:

 Male/Female

Power Supply

4 AA alkaline batteries

Battery Life

Approximately 6 months (When AA alkaline batteries are used with four 
measurements and data transfers a day at a room temperature of 23ºC.)

Operating Temperature
/Humidity

+50°F to +104°F (+10°C to +40°C), 30 to 85% RH

Storage Temperature
/Humidity/Air Pressure

–4°F to +140°F (–20°C to +60°C), 10 to 95% RH, 700 - 1060 hPa

External Dimensions

Approximately 11 3/4" (W) x 1 1/2" (H) x 11 3/8" (D)

Weight

Approximately 4 lb (including batteries)

Contents

Body Composition Monitor, 4 AA Alkaline Batteries, Instruction Manual

HBF-206IT-Z_B_M.fm  Page 42  Monday, February 22, 2010  4:24 PM

Содержание HBF-206IT

Страница 1: ...Instruction Manual Bluetooth Body Composition Monitor Model HBF 206IT ...

Страница 2: ...4 Operating Instructions Battery Installation 16 Setting the Date and Time 18 Setting Personal Data 20 Selecting Measurement Unit 22 Changing Personal Data 23 Deleting Personal Data 24 How to Take a Measurement 25 Understanding Your Measurement Results 28 How to Measure Weight Only 29 Viewing the Last Measurement Results 30 Transferring the Data 32 About the Wireless Communications Function 35 Car...

Страница 3: ... the measurement platform The personal memory function can be used to store data for up to four personal profiles This product comes with the following components Monitor Instruction Manual 4 AA Alkaline Batteries CAUTION Read all of the information in the instruction manual and any other literature in the box before operating the unit Fill in for future reference DATE PURCHASED SERIAL NUMBER Stap...

Страница 4: ...al and any other literature in the box before operating the unit Do not use microwave ovens or other devices that generate strong electrical or electromagnetic fields near the monitor This may result in an operational failure Do not use mobile phones near the unit except for wireless communications Interference from the phone may make it difficult to obtain accurate measurements Do not step on the...

Страница 5: ...essories according to applicable local regulations Unlawful disposal may cause environmental pollution Operate the unit only as intended Do not use for any other purpose This unit is intended for home use only It is not intended for professional use in hospitals or other medical facilities This unit does not support the standards required for professional use Always wash your feet before using the...

Страница 6: ...rmine the amount of water in each tissue You will not notice or feel the electrical current BODY MASS INDEX Body Mass Index BMI is a number calculated from a person s weight and height BMI is a reliable indicator of body fatness for people BMI does not measure body fat directly but research has shown that BMI correlates with direct measures of body fat BMI is used as a screening tool to identify p...

Страница 7: ...y fat in men and women is different so the basis for classifying the body fat percentage is different between the genders Interpreting the Body Fat Percentage Result The table below is based on research by Gallagher et al American Journal of Clinical Nutrition Vol 72 Sept 2000 and classified into four levels by Omron Healthcare Gender Age Low 0 Normal High Very High Female 20 39 21 0 21 0 32 9 33 ...

Страница 8: ...ls of fat in the bloodstream which may lead to conditions such as high cholesterol heart disease and type 2 diabetes In order to prevent or improve these conditions it is important to try to reduce the amount of visceral fat levels to an acceptable level Interpreting the Visceral Fat Level Result MRI Cross Section at the Navel Level Subcutaneous Fat Visceral Fat Spine 0 Normal High Visceral Fat Le...

Страница 9: ... of these is 60 70 for resting metabolism 20 30 for daily activity and 10 for diet induced thermogenesis This means that resting metabolism accounts for most of our daily energy consumption If our daily caloric intake exceeds the amount of energy required for these activities the additional calories can be stored as fat Resting metabolism Energy required to maintain vital functions Daily activity ...

Страница 10: ...ound weight gain The maintenance and increase of skeletal muscle is closely linked to resting metabolism rate Interpreting the Skeletal Muscle Percentage Result Source Omron Healthcare BODY AGE Body age is based on your resting metabolism Body age is calculated by using your weight body fat percentage and skeletal muscle percentage to produce a guide to whether your body age is above or below the ...

Страница 11: ...gain The monitor tracks your progress by monitoring weight skeletal muscle body fat BMI and resting metabolism rate to help you reach your goals Here s a comparison of losing weight quickly versus slowly Use the separate Measurement Log Sheet to help you understand your body composition results WARNING Contact your physician or healthcare provider before beginning a weight reduction or exercise pr...

Страница 12: ...nts Under the Following Conditions Immediately after vigorous exercise after a bath or sauna After drinking alcohol or a large amount of water after a meal about 2 hours If a measurement is taken under these physical conditions the calculated body composition may differ significantly from the actual one because the water content in the body is changing Daily activities Waking up Breakfast Lunch Di...

Страница 13: ...ated to changing ratios of body fluid and or body composition The body fat percentage measured by this monitor may significantly differ from the actual body fat percentage for the following people Elderly people People with a fever Body builders or highly trained athletes Persons undergoing dialysis Persons with osteoporosis who have very low bone density Pregnant women Persons with edema swelling...

Страница 14: ...rt beeps When data has been sent successfully Blip Blip When data failed to be sent Beep Beep Beep A series of three long beeps Main Unit Err OK P Indicators UPLOAD Button Display Personal Profile Number Button Turns the power ON and selects body composition measurement GUEST MEMO Button Turns the power ON and selects GUEST mode SET MODE Button WEIGHT OFF Button Turns the power ON and selects weig...

Страница 15: ...s measurement results are displayed 5 30 seconds after the result is displayed when measuring weight only 6 10 seconds after the Err symbol appears on the display NOTE The OFF symbol appears on the display when the power is turned off Body Fat Percentage Skeletal Muscle Percentage and Visceral Fat Level Classification Bar Birth Date Indicator Display Delete Indicator Personal Profile Number Height...

Страница 16: ...2 Pull the tab of the cover upwards 2 Install 4 AA size alkaline batteries so the positive and negative polarities match the polarities of the battery compartment as indicated in the battery compartment 3 Replace the battery cover 1 Align the hooks on the battery cover with the slots in the battery compartment 2 Push the battery cover until the tab clicks into place Back Tab ...

Страница 17: ... used with four measurements and data transfers a day at a room temperature of 23ºC Trial batteries supplied with the unit may have a shorter life WARNING If battery fluid should get in your eyes immediately rinse with plenty of clean water Contact your physician immediately CAUTION If battery fluid should get on your skin or clothing immediately rinse with plenty of clean water CAUTION Remove the...

Страница 18: ...n The year is set The month flashes on the display 3 1 Press the GUEST MEMO button to change the month 2 Press the SET MODE button The month is set The day flashes on the display Buttons Used in this Procedure GUEST MEMO Button Press this button to advance one Press continuously to rapidly advance SET MODE Button Use this button to confirm the setting and or move to the next item after confirming ...

Страница 19: ...ton to change the minute 2 Press the SET MODE button The current settings for the year month and day hour and minute appear in this sequence on the display The monitor automatically turns off TO ADJUST THE DATE AND TIME 1 Press the WEIGHT OFF button to turn the monitor ON The current date appears on the display then the display changes to 0 0 lb 2 Press the SET MODE button for 2 seconds or longer ...

Страница 20: ...rsonal Profile Number or the Guest mode A Personal Profile Number Press the desired Personal Profile Number button 1 through 4 The current date appears on the display then the display changes to the birth date 1940 NOTE When the date of birth rather than current date is displayed the settings for that personal profile number are finished Please use a different number or delete your personal profil...

Страница 21: ...e the birth month 4 Press the SET MODE button The birth month is set The birth day blinks on the display 5 Press the GUEST MEMO button to change the birth day 6 Press the SET MODE button The birth day is set The gender symbols blink on the display Set the gender to male or female 1 Press the GUEST MEMO button to change the gender 2 Press the SET MODE button The gender is set The default value for ...

Страница 22: ...ges 25 to 27 SELECTING MEASUREMENT UNIT You can change the measurement units used for the height and weight settings 1 Press the WEIGHT OFF button to turn the monitor ON The current date appears on the display then the display changes to 0 0 lb Wait until 0 0 lb appears on the display 2 Press and hold the GUEST MEMO button until lb and kg blink on the display 3 Press the GUEST MEMO button to selec...

Страница 23: ...ent results to be calculated correctly 1 Press the Personal Profile Number button to turn the monitor ON The birth date appears on the display then the display changes to 0 0 lb Wait until 0 0 lb appears on the display 2 Press the SET MODE button The current setting for birth year blinks on the display 3 Refer to Step 2 on pages 21 and 22 to enter your personal data ...

Страница 24: ... setting for birth year blinks on the display 3 Press and hold the GUEST MEMO button until the and DEL symbol blink on the display 4 Press the SET MODE button The DEL OK symbol blinks on the display 5 Press the SET MODE button The Clr symbol appears on the display and the birth year setting appears on the display NOTE To cancel deleting press the GUEST MEMO button 6 Refer to Step 2 on pages 21 and...

Страница 25: ...n the display NOTES If you step onto the monitor before 0 0 lb appears on the display an error message Err will appear If the following appears on the display no personal data was entered for the number you selected Refer to SETTING PERSONAL DATA on pages 21 and 22 B Guest mode 1 Press the GUEST MEMO button to turn the monitor ON The current date appears on the display then the Guest indicator app...

Страница 26: ...urement is completed your weight is displayed again Step off the unit Postures to Avoid During Measurement Incorrect posture may result in inaccurate measurement of body composition The display will show your weight and then the weight result will blink twice The monitor will start to calculate body composition During body composition measurement moves to show the measurement is progressing Standi...

Страница 27: ...utton The display changes with each press of the SET MODE button as shown below NOTE Use the bar indicator as a guide to measurement 4 Press the WEIGHT OFF button to turn the monitor off Skeletal Muscle Percentage Classification WEIGHT BODY FAT PERCENTAGE RESTING METABOLISM Visceral Fat Level Classification BODY AGE SKELETAL MUSCLE PERCENTAGE VISCERAL FAT LEVEL BMI Body Fat Percentage Classificati...

Страница 28: ...r Age Low 0 Normal High Very High Female 20 39 21 0 21 0 32 9 33 0 38 9 39 0 40 59 23 0 23 0 33 9 34 0 39 9 40 0 60 80 24 0 24 0 35 9 36 0 41 9 42 0 Male 20 39 8 0 8 0 19 9 20 0 24 9 25 0 40 59 11 0 11 0 21 9 22 0 27 9 28 0 60 80 13 0 13 0 24 9 25 0 29 9 30 0 Gender Age Low 0 Normal High Very High Female 18 39 24 3 24 3 30 3 30 4 35 3 35 4 40 59 24 1 24 1 30 1 30 2 35 1 35 2 60 80 23 9 23 9 29 9 3...

Страница 29: ...lected setting To change the measurement unit 1 Keep the GUEST MEMO button pressed until lb and kg blink on the display 2 Press the GUEST MEMO button to select the desired measurement unit lb or kg This will automatically change cm and feet inch under height setting 3 Press the SET MODE button to confirm the change 2 Step onto the unit Stand with your weight evenly distributed on the measurement p...

Страница 30: ...EMO button The last weight value is displayed If you have measured your body composition in step 2 each press of the GUEST MEMO button alternates between the current measurement result and the last previous result NOTES If there are no results for the last measurement the symbol is displayed If you have not measured your body composition in step 2 current measurement results cannot be displayed ev...

Страница 31: ...easurement values NOTE Refer to TRANSFERRING THE DATA on pages 32 to 34 if you want to transfer the data 5 Press the WEIGHT OFF button to turn the monitor off Last body fat percentage Last visceral fat level Last resting metabolism Last body age Last BMI Last weight Last skeletal muscle percentage ...

Страница 32: ...Refer to TRANSFERRING THE DATA on page 33 for information about transferring the data with a device that has already been paired with the unit 1 Display the measurement results Pairing Registration after taking a measurement Refer to HOW TO TAKE A MEASUREMENT on page 25 to display the measurement results Pairing Registration without taking a measurement Refer to VIEWING THE LAST MEASUREMENT RESULT...

Страница 33: ...on on the connected device then repeat the procedure from step 2 to try again TRANSFERRING THE DATA 1 Display the measurement results Transferring data after taking a measurement Refer to HOW TO TAKE A MEASUREMENT on page 25 to display the measurement results Transferring data without taking a measurement Refer to VIEWING THE LAST MEASUREMENT RESULTS on page 30 to display the results for the last ...

Страница 34: ...at the procedure from step 2 to try again 4 Press the WEIGHT OFF button to turn the monitor off NOTE If you forget to turn the monitor off the screen will return to the screen displayed before data transmission started after 10 seconds About Data FULL Indicator Up to 30 sets of measurement results can be stored for each personal profile number If the number exceeds 30 the oldest results are delete...

Страница 35: ...devices including microwave oven and wireless LAN which operate same frequency band of this Product there is a possibility that interference occurs between this Product and such other devices If such interference occurs please stop the operation of other devices or relocate this Product before using this Product or do not use this Product around the other wireless devices The Bluetooth word mark a...

Страница 36: ...on page 26 Your feet are too dry Slightly moisten your soles of your feet with a damp towel and retake the measurement Device error Turn the monitor off and on again Take the measurement If this error still occurs consult your OMRON service representative You stepped onto the measurement platform before 0 0 lb was displayed Wait until 0 0 lb is displayed before stepping onto the measurement platfo...

Страница 37: ... circulation is back to normal The electrodes are extremely cold Place the unit in a warm room for a few minutes and then take a measurement when the electrodes no longer feel cold Feet are too dry Slightly moisten the soles of your feet with a damp towel and try again is displayed for some of the results The personal data settings or body composition values are outside the measurable range Check ...

Страница 38: ...e that Personal Profile Number 1 2 3 4 or Guest is displayed before measurement Refer to HOW TO TAKE A MEASUREMENT on page 25 Data cannot be sent Err indicator lights The destination device for the data is too far away After checking that there are no sources of interference nearby move the device to a distance within 5 m of the unit Pairing registering has not been completed Perform pairing regis...

Страница 39: ...nlight extreme hot or cold temperatures or humidity Thoroughly dry any moisture off the monitor before storing Remove the batteries if the monitor will not be used for three months or longer Use the monitor consistent with the instruction provided in this manual CAUTION Do not submerge the device or any of the components in water CAUTION Do not subject the monitor to strong shocks such as dropping...

Страница 40: ... one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the product and the receiver Connect the product into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help POTENTIAL FOR RADIO TELEVISION INTERFERENCE for Canada only This digital apparatus does ...

Страница 41: ...ecific problem Pack the product carefully to prevent damage in transit Because of possible loss in transit we recommend insuring the product with return receipt requested THE FOREGOING IS THE SOLE WARRANTY PROVIDED BY OMRON IN CONNECTION WITH THIS PRODUCT AND OMRON HEREBY DISCLAIMS ANY OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR ...

Страница 42: ...bolism rate Visceral Fat Level Visceral Fat Level Classification and Body age is 18 to 80 years old The age range for the Body Fat Percentage Classification is 20 to 80 years old Memory Display memory Last previous measurement results Unit stored memory Up to 30 sets Transmission protocol Bluetooth wireless technology Version 2 1 EDR Class 2 Set Ranges Personal data Information The following infor...

Страница 43: ...43 NOTES ...

Страница 44: ...Distributed by Omron Healthcare Inc 1200 Lakeside Drive Bannockburn Illinois 60015 www omronhealthcare com Copyright 2010 Omron Healthcare Inc Made in China 5328803 5B ...

Отзывы: