H3CR-G
H3CR-G
44
Accessories (Order Separately)
Name/specifications
Models
Flush Mounting Adapter
Y92F-30
g
p
Y92F-70
Y92F-71
Mounting Track
50 cm (
l
) x 7.3 mm (t)
PFP-50N
1 m (
l
) x 7.3 mm (t)
PFP-100N
1 m (
l
) x 16 mm (t)
PFP-100N2
End Plate
PFP-M
Spacer
PFP-S
Protective Cover
Y92A-48B
Track Mounting/
Front Connecting Socket
8-pin
P2CF-08
Back Connecting Socket
P3G-08
Time Setting Ring
Setting a specific time
Y92S-27
Limiting the Setting Range
Y92S-28
Panel Cover (see note)
Light Gray (5Y7/1)
Y92P-48GL
Black (N1.5)
Y92P-48GB
Medium Gray (5Y5/1)
Y92P-48GM
Hold-down Clip
For PL08 and PL11 Sockets
Y92H-1
For PF085A Socket
Y92H-2
Note:
The Time Setting Ring and Panel Cover are sold together.
Specifications
General
Item
H3CR-G8L
H3CR-G8EL
Functions
Star-delta timer
Star-delta timer with instantaneous output
Pin type
8-pin
Operating/Reset method
Time-limit operation/Self-reset
Output type
Time-limit: SPST-NO (star operation circuit)
SPST-NO (delta operation circuit)
Time-limit:
SPST-NO (star operation circuit)
SPST-NO (delta operation circuit)
Instantaneous: SPST-NO
Mounting method
DIN track mounting, surface mounting, and flush mounting
EMC
Emission Enclosure:
EN55011 Group 1 class A
Emission AC Mains:
EN55011 Group 1 class A
Immunity ESD:
IEC801-2:
4 kV contact discharge (level 2)
8 kV air discharge (level 3)
Immunity RF-interference:
ENV50140: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity Conducted Disturbance: ENV50141: 10 V (0.15 to 80 MHz) (level 3)
Immunity Burst:
IEC801-4:
2 kV power-line (level 3)
2 kV I/O signal-line (level 4)
Approved standards
UL508, CSA C22.2 No.14, LR/NK
Conforms to VDE0435/2021, VDE0110
Conforms to EN50081-2, prEN50082-2