User’s Manual
Checklists
The test rod is detected when it is moved around in the detection zone as shown in the diagram below.
In other words, when a test rod is inserted into the detection zone, the OSSD indicator turns red.
The F3SG-PG detects the test rod when the test rod is moved on the optical axis pitch. That is, when
the test rod is moved from the sensor end to the sensor end, the OSSD indicator light turns red only
by the number of optical axes.
When the Fixed Blanking function is used, you must ensure that all blanked zones in the detection
zone are covered by a hard barrier guard and there must be no zone in the detection zone where the
test rod goes undetected.
The object resolution may vary depending on the models of the F3SG-SR and settings of the Floating
Blanking function or Reduced Resolution function. Use a test rod with an appropriate diameter for
inspection. A test rod is not included in the F3SG-SR product package.
When the Muting function is used, installation condition of muting sensor must not be changed.
When the Muting function is used, the MUTING state can be checked from where a worker operates
or adjust the machine.
Neither connector, cap, or bracket must be loose.
7-2-1-2. Checking that Hazardous Parts Stop While the Machine Operates
The hazardous parts are movable when nothing is in the detection zone.
The hazardous parts stop immediately when a test rod is inserted into the detection zone at 3
positions: "directly in front of the emitter", "directly in front of the receiver", and "between the emitter
and receiver". (Use the appropriate test rod.)
The hazardous parts remain stopped as long as the test rod is in the detection zone.
The hazardous parts stop when the power of the F3SG-SR/PG is turned OFF while nothing is in the
detection zone.
7-2-1-3. Items to Inspect Every 6 Months or When Machine Settings Are Changed
In addition to inspection item at operation start, following items must also be verified.
The outputs of the F3SG-SR/PG and the machine are properly wired.
The total number of times that the control relays/contactors have switched is significantly lower than
their design lives.
There is no ambient light.
Start
Stop
<F3SG-SR>
<F3SG-PG>
Start
Start
Start
Stop
Stop
Stop
Содержание F3SG-PG Series
Страница 18: ...xvi Introduction F3SG SR PG User s Manual...
Страница 30: ...xxviii Introduction F3SG SR PG User s Manual...
Страница 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Страница 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Страница 226: ...196 Chapter 3 Intelligent Tap Application Example F3SG SR PG User s Manual Setting with Intelligent Tap...
Страница 430: ...400 Chapter 6 Connectable Safety Control Units F3SG SR PG User s Manual Input Output Circuit and Applications...
Страница 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...