F3SG-RA
1
6
Standard Muting Mode/Exit-Only Muting Mode with two Muting Sensors using NPN Outputs
The following is the example of External Device Monitoring enabled, Auto Reset mode, NPN output and External Test in 0
V
Active.
DIP Switch settings *3
: Indicates a switch position.
Configure functions with the DIP Switches before wiring.
Wiring Example
Function
DIP-SW1
DIP-SW2
Receiver
EDM Enabled
Auto Reset (factory default setting)
NPN
Emitter
External Test: 0
V
Active
2
O
N
2
O
N
3
O
N
3
O
N
4
O
N
4
O
N
7
O
N
7
O
N
4
O
N
Un
b
locked
Blocked
MUTE A
Beam state
MUTE B
OSSD
Test S
w
itch (S1)
OSSD1 : Black
OSSD2 : White
24 VDC
: Bro
w
n
N
ot
u
sed : Yello
w
TEST : Black
N
ot
u
sed : White
24 VDC
: Bro
w
n
0 VDC
: Bl
u
e
Recei
v
er
Emitter
0 VDC
: Bl
u
e
AUX : Red
MUTE B : Pink
MUTE A : Gray
RESET : Yello
w
*1
S1: Test S
w
itch (Connect the line to 24 V if this s
w
itch is
not re
qu
ired)
S2: O
v
erride Cancel S
w
itch
S3: Locko
u
t/Interlock Reset S
w
itch or O
v
erride S
w
itch
KM1, KM2: Safety relay
w
ith forci
b
ly g
u
ided contacts (G7SA)
or magnetic contactor
M: 3-phase motor
ML: M
u
ting lamp
A1, B1: M
u
ting sensor
S1
S3
M
u
ting
Sensor
(
N
P
N
o
u
tp
u
t)
Reflector
S2
*2
A1
B1
Po
w
er S
u
pply
+24 VDC
0 VDC
ML
KM1
KM2
KM1
KM2
KM1
KM2
M
F39-JG
@
A-L
F39-JG
@
A-D
*1.Also used as Override input line.
*2.Make sure to connect an override cancel switch to the Reset line
when using the override function. Otherwise the override state
may not be released by the override cancel switch, resulting in
serious injury.
*3.The functions are configurable with DIP Switch. Refer to
Safety
Light Curtain F3SG-R Series User's Manual
for more information