F3SG-RA
1
9
Pre-Resest Mode using PNP Output
The following is the example of External Device Monitoring disabled, Pre-Reset mode, PNP output and External Test in 24
V
Active.
DIP Switch settings *4
: Indicates a switch position.
Configure functions with the DIP Switches before wiring.
Wiring Example
Connectable Safety Control Units
The F3SG-RA with PNP output can be connected to the safety control units listed in the table below.
Function
DIP-SW1
DIP-SW2
Receiver
EDM Disabled (factory default setting)
Pre-Reset
PNP (factory default setting)
Emitter
External Test: 24
V
Active (factory default setting)
Connectable Safety Control Units (PNP output)
G9SA-301
G9SA-321
G9SA-501
G9SB-200-B
G9SB-200-D
G9SB-301-B
G9SB-301-D
G9SE-201
G9SE-401
G9SE-221-T
@
G9SX-AD322-T
G9SX-ADA222-T
G9SX-BC202
G9SX-GS226-T15
G9SP-N10S
G9SP-N10D
G9SP-N20S
NE0A-SCPU01
NE1A-SCPU01
NE1A-SCPU02
DST1-ID12SL
DST1-MD16SL
DST1-MRD08SL
NX-SIH400
NX-SID800
F3SP-T01
2
O
N
2
O
N
3
O
N
3
O
N
4
O
N
4
O
N
7
O
N
7
O
N
4
O
N
OS
SD1 : Black
OS
SD2 : White
24 VDC : Bro
w
n
N
ot
u
sed : Yello
w
TEST : Black
N
ot
u
sed : White
24 VDC : Bro
w
n
0 VDC : Bl
u
e
Recei
v
er
Emitter
0 VDC : Bl
u
e
AUX : Red
N
ot
u
sed : Pink
PRE-RESET : Gray
RESET : Yello
w
S1: Test S
w
itch (Connect the line to 0 V if this s
w
itch is
not re
qu
ired)
S2: Locko
u
t/Interlock Reset S
w
itch
S3: Pre-Reset S
w
itch
PLC: Programma
b
le controller
(Used for monitoring only.
N
OT related to safety system.)
S2
S3
F39-JG
@
A-L
F39-JG
@
A-D
S1
Po
w
er S
u
pply
+24 VDC
0 VDC
Safety
Controller *1 *2
I
N
1
I
N
2
PLC *3
I
N
Pre-Reset S
w
itch (S3)
Beam state
Reset S
w
itch (S2)
OSSD
Un
b
locked
Blocked
T1: P
u
sh time: m
u
st
b
e T1 >= 300ms
T2: Pre-reset limit time
b
et
w
een Pre-reset and Reset: m
u
st
b
e T2 <= 60s
T3: P
u
sh time: m
u
st
b
e T3 >= 300ms
T1
T2
T3
*1.Refer to the following list "Connectable Safety Control
Units" on this page.
*2.The safety controller and the F3SG-R must share the
power supply or be connected to the common terminal
of the power supply.
*3.
W
hen connecting to the PLC, the output mode must be
changed with the Configuration Tool.
*4.The functions are configurable with DIP Switch. Refer to
Safety Light Curtain F3SG-R Series User's Manual
for
more information on setting the functions by the DIP
Switch.