F3SG-RA
1
3
Standard Muting Mode/Exit-Only Muting Mode using PNP Outputs
The following is the example of External Device Monitoring disabled, Auto Reset mode, PNP output and External Test in 24
V
Active.
DIP Switch settings *6
: Indicates a switch position.
Configure functions with the DIP Switches before wiring.
Wiring Example
Function
DIP-SW1
DIP-SW2
Receiver
EDM Disabled (factory default setting)
Auto Reset (factory default setting)
PNP (factory default setting)
Emitter
External Test: 24
V
Active (factory default setting)
2
O
N
2
O
N
3
O
N
3
O
N
4
O
N
4
O
N
7
O
N
7
O
N
4
O
N
OSSD1 : Black
OSSD2 : White
24 VDC : Bro
w
n
N
ot
u
sed : Yello
w
TEST : Black
N
ot
u
sed : White
24 VDC : Bro
w
n
0 VDC
: Bl
u
e
Recei
v
er
Emitter
0 VDC
: Bl
u
e
AUX : Red
MUTE B : Pink
MUTE A : Gray
RESET : Yello
w
*1
S1: Test S
w
itch (Connect the line to 0 V if this s
w
itch
is not re
qu
ired)
S2: Locko
u
t/Interlock Reset S
w
itch,
O
v
erride S
w
itch
or O
v
erride Cancel S
w
itch
ML: M
u
ting lamp
S2
*2
F39-JG
@
A-L
F39-JG
@
A-D
S1
Po
w
er S
u
pply
+24 VDC
0 VDC
Safety
Controller *3 *4
M
u
ting
Act
u
ator *5
I
N
1
I
N
2
ML
Un
b
locked
Blocked
MUTE A
MUTE B
OSSD
Test S
w
itch (S1)
Beam state
*1.Also used as Override input line.
*2.Make sure to connect an override cancel switch to the Reset
line when using the override function. Otherwise the override
state may not be released by the override cancel switch,
resulting in serious injury.
*3.Refer to page 29 for more information.
*4.The safety controller and the F3SG-R must share the power
supply or be connected to the common terminal of the power
supply.
*5.Refer to
Smart Muting Actuator F3W-MA Series User's Manual
for more information.
*6.The functions are configurable with DIP Switch. Refer to
Safety Light Curtain F3SG-R Series User's Manual
for more
information on setting the functions by the DIP Switch.