F3SG-RA
7
Environ-
mental
Ambient Temperature
Operating
-10 to 55°C (14 to 131°F) (non-icing)
Storage
-25 to 70°C (-13 to 158°F)
Ambient Humidity
Operating
35% to 85% (non-condensing)
Storage
35% to 95%
Ambient Illuminance
Incandescent lamp: 3,000 Ix max. on receiver surface
Sunlight: 10,000 Ix max. on receiver surface
Degree of Protection (IEC 60529)
IP65 and IP67
Vibration Resistance (IEC 61496-1)
10 to 55 Hz, Multiple amplitude of 0.7 mm, 20 sweeps for all 3 axes
Shock Resistance (IEC 61496-1)
100 m/s
2
, 1000 shocks for all 3 axes
Pollution Degree (IEC 60664-1)
Pollution Degree 3
Connec-
tions
Power cable
Type of Connection
M12 connectors: 5-pin emitter and 8-pin receiver, IP67 rated when mated, Cables prewired to the sensors
Number of Wires
Emitter: 5, Receiver: 8
Cable Length
0.3 m
Cable Diameter
6 mm
Minimum Bending
Radius
R5 mm
Cascading cable
Type of Connection
M12 connectors: 5-pin emitter and 8-pin receiver, IP67 rated when mated
Number of Wires
Emitter: 5, Receiver: 8
Cable Length
0.2 m
Cable Diameter
6 mm
Minimum Bending
Radius
R5 mm
Extension cable
- Single-ended cable
- Double-ended cable
Type of Connection
M12 connectors: 5-pin emitter and 8-pin receiver, IP67 rated when mated
Number of Wires
Emitter: 5, Receiver: 8
Cable Length
Refer to page 3.
Cable Diameter
6.6 mm
Minimum Bending
Radius
R36 mm
Extension of Power Cable
100 m max.
Material
Material
Housing: Aluminum
Cap: PBT
Front window: PMMA
Cable: Oil resistant P
V
C
Mounting Bracket: ZDC2
FE plate: SUS
Weight (packaged)
Refer to page
8.
Included Accessories
Safety Precautions, Quick Installation Manual, Standard Fixed Bracket*, Troubleshooting Guide
Sticker,
W
arning Zone Label
* The quantity of Standard Fixed Brackets included varies depending on the protective height.
[F3SG-
RA
-14]
- Protective height of 0160 to 1200: 2 sets
- Protective height of 1280 to 2080: 3 sets
[F3SG-
RA
-30]
- Protective height of 0190 to 1230: 2 sets
- Protective height of 1310 to 2270: 3 sets
- Protective height of 2350 to 2510: 4 sets
Conformity
Conforming standards
Refer to page 19.
Type of ESPE (IEC 61496-1)
Type 4
Performance Level
(PL)/Safety category
Type 4
PL e/Category 4 (EN ISO 13849-1:2008)
PFHd
1.1 × 10
-8
(IEC 61508)
Proof test interval T
M
Every 20 years (IEC 61508)
SFF
99% (IEC 61508)
HFT
1 (IEC 61508)
Classification
Type B (IEC 61508-2)
F3SG-4RA
-14
F3SG-4RA
-30