manualshive.com logo in svg
background image

Terms and Conditions Agreement 

 
Read and understand this catalog. 
Please read and understand this catalog before purchasing the products.    Please consult your OMRON representative if you 
have any questions or comments.     
 
Warranties. 
(a) Exclusive Warranty

. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship 

for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron 
disclaims all other warranties, express or implied. 
(b)  Limitations.  OMRON  MAKES  NO  WARRANTY  OR  REPRESENTATION,  EXPRESS  OR  IMPLIED,  ABOUT 
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER 
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE 
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. 
Omron  further  disclaims  all  warranties  and  responsibility  of  any  type  for  claims  or  expenses  based  on  infringement  by  the 
Products  or  otherwise  of  any  intellectual  property  right.  (c)  Buyer  Re

medy.  Omron’s  sole  obligation  hereunder  shall  be,  at 

Omron’s  election,  to  (i)  replace  (in  the  form  originally  shipped  with  Buyer  responsible  for  labor  charges  for  removal  or 

replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount 
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, 
repair, indemnity or any other claims or expenses regarding the Products unless Omron

’s analysis confirms that the Products 

were  properly  handled,  stored,  installed  and  maintained  and  not  subject  to  contamination,  abuse,  misuse  or  inappropriate 
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall 
not  be  liable  for  the  suitability  or  unsuitability  or  the  results  from  the  use  of  Products  in  combination  with  any  electrical  or 
electronic  components,  circuits,  system  assemblies  or  any  other  materials  or  substances  or  environments.  Any  advice, 
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above 
warranty. 
See 

http://www.omron.com/global/

    or contact your Omron representative for published information. 

 
Limitation on Liability; Etc. 
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, 
LOSS  OF  PROFITS  OR  PRODUCTION  OR  COMMERCIAL  LOSS  IN  ANY  WAY  CONNECTED  WITH  THE  PRODUCTS, 
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. 
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. 
 
Suitability of Use. 
Omron  Companies  shall  not  be  responsible  for  conformity  with  any  standards,  codes  or  regulations  which  apply  to  the 

combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable 

third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself 
is  not  sufficient  for  a  complete  determination  of  the  suitability  of  the  Product  in  combination  with  the  end  product,  machine, 
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product 

with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. 

 

NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE 
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, 
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE 
OVERALL EQUIPMENT OR SYSTEM. 
 
Programmable Products. 

Omron  Companies  shall  not  be  responsible  for  the  user’s  programming  of  a  programmable  Product,  or  any  consequence 

thereof. 
 
Performance Data. 
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining 

suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate 

it to actual application requirements. Actual performance is subject to the Om

ron’s Warranty and Limitations of Liability.

 

 
Change in Specifications. 
Product  specifications  and  accessories  may  be  changed  at  any  time  based  on  improvements  and  other  reasons.  It  is  our 
practice to change part numbers when published ratings or features are changed, or when significant construction changes are 
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers 
may be assigned to fix or establish key specifications for your application. 

Please consult with your Omron’s representative at 

any time to confirm actual specifications of purchased Product. 
 
Errors and Omissions. 

Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is 

assumed for clerical, typographical or proofreading errors or omissions.

 

 

 

 

2015.8 

In the interest of product improvement, specifications are subject to change without notice. 

OMRON Corporation 

Industrial Automation Company 

 

http://www.ia.omron.com/ 

(c)Copyright OMRON Corporation 2015 All Right Reserved. 

Buy Now: www.ValinOnline.com | Phone: 800-774-5630 | Email: [email protected]

Содержание E5CN-HC2M-500

Страница 1: ...or the most recent information on models that have been certified for safety standards refer to your OMRON website Universal Sensor Inputs Universal thermocouple Pt analog current voltage inputs Indication Accuracy Thermocouple Pt input 0 1 of PV Analog input 0 1 FS 2 level Display PV and SV 5 digit Display with high resolution of 0 01 C E5CN H Event Inputs None Two Sampling Period 60 ms Control O...

Страница 2: ...r overcurrent detection CT1 HH Heater burnout SSR failure Heater overcurrent detection CT2 B Two event inputs 03 RS 485 communications H03 Heater burnout SSR failure Heater overcurrent detection CT1 RS 485 communications HB Heater burnout SSR failure Heater overcurrent detection CT1 Two event inputs HH03 Heater burnout SSR failure Heater overcurrent detection CT2 RS 485 communications H01 Heater b...

Страница 3: ...elay output E5CN HR2MD W 500 Voltage output for driving SSR E5CN HQ2MD W 500 Current output E5CN HC2MD W 500 Functions Model Communications RS 485 3 phase heater burnout SSR failure Heater overcurrent detection E53 CNHH03N2 Heater burnout SSR failure Heater overcurrent detection Event inputs E53 CNHBN2 Communications RS 485 Control output 2 Voltage for driving SSR E53 CNQ03N2 Communications RS 485...

Страница 4: ...ow Approx 7 mA per contact Logic opera tions Number of operations 8 max Combinations can be made using work bits Operations Logic operation Any of the following four patterns can be selected The input status may be inverted A and B or C and D A or C and B or D A or B or C or D A and B and C and D A B C and D are four inputs Delay ON delay or OFF delay for the results of the logic operation given a...

Страница 5: ...0 500 0 500 0 400 0 400 0 400 0 400 0 400 0 200 00 200 00 200 00 200 00 100 0 100 0 100 0 0 0 0 0 0 0 0 0 0 0 0 0 50 00 20 0 50 00 100 0 20 0 50 00 50 00 100 0 200 0 199 9 199 9 200 0 200 0 199 9 200 0 200 0 199 9 200 0 Setting number 0 1 2 24 3 4 5 6 21 7 8 22 9 10 23 11 12 13 14 15 16 17 18 19 20 25 26 27 28 29 Shaded settings are the default settings The applicable standards for the input types...

Страница 6: ...n alarm value X is negative 0 Alarm function OFF Output OFF No alarm 1 1 Upper and lower limit 2 Set the deviation in the set point by setting the alarm upper limit H and alarm lower limit L 2 Upper limit Set the upward deviation in the set point by setting the alarm value X 3 Lower limit Set the downward deviation in the set point by setting the alarm value X 4 1 Upper and lower limit range 3 Set...

Страница 7: ...roportional band P Temperature input 0 1 to 3240 0 C or F in units of 0 1 C or F Analog input 0 1 to 999 9 FS in units of 0 1 FS Integral time I 0 0 to 3240 0 s in units of 0 1 s Derivative time D 0 0 to 3240 0 s in units of 0 1 s Control period 0 5 1 to 99 s in units of 1 s Manual reset value 0 0 to 100 0 in units of 0 1 Alarm setting range 19999 to 32400 decimal point position depends on input t...

Страница 8: ...ge 5 VDC Current consumption 70 mA Ambient operating temperature 0 to 55 C with no condensation or icing Ambient operating humidity 10 to 80 Storage temperature 20 to 60 C with no condensation or icing Storage humidity 10 to 80 Altitude 2 000 m max Weight Approx 100 g Transmission line connection method RS 485 Multipoint RS 232C Point to point Communications RS 485 two wire half duplex RS 232C Syn...

Страница 9: ... and Transfer Output 11 12 13 14 15 EV1 EV2 Event Inputs E53 CNBN2 E53 CNQHHN2 11 12 13 14 15 CT1 Control Output 2 and CT E53 CNQHN2 E53 CN03N2 E53 CNQ03N2 E53 CNH03N2 E53 CNHH03N2 E53 CNQFN2 E53 CN01N2 E53 CNH01N2 E53 CNQ01N2 E53 CNQBN2 E53 CNHBN2 E53 CNBFN2 SD RS 232C RD SG SD RD SG RS 232C 11 12 13 14 15 Communications RS 232 SD RD SG 11 12 13 14 15 11 12 13 14 15 RS 485 Communications RS 485 a...

Страница 10: ...ofing Panel Cutout Mounted Separately Group Mounted 48 48 44 8 44 8 48 8 6 1 5 91 78 58 Terminal Cover E53 COV17 Accessory Mounting Adapter Accessory Waterproof Packing Accessory E5CN H Recommended panel thickness is 1 to 5 mm Group mounting is not possible in the vertical direction Maintain the specified mounting space between Controllers To mount the Controller so that it is waterproof insert th...

Страница 11: ...n not be used E54 CT3 Accessory Armature 30 21 15 5 8 dia 25 3 40 10 5 2 8 7 5 10 Two 3 5 dia 40 40 30 12 dia 9 2 36 dia 15 30 Two M3 depth 4 Approx 3 dia 18 22 Approx 6 dia Plug Armature Lead E54 CT1 E54 CT3 Connection Example Plug E54 CT1 Thru current Io vs Output Voltage Eo Reference Values Maximum continuous heater current 50 A 50 60 Hz Number of windings 400 2 Winding resistance 18 2 Ω Thru c...

Страница 12: ...nted to E5CN H Note 1 Use this Adapter when the panel has already been prepared for the E5B 2 The Adapter is available only in black 50 61 3 5 38 48 100 5 Y92F 52 Note This Adapter cannot be used together with the Terminal Cover Remove the Terminal Cover to use the Adapter Mounted to E5CN H Buy Now www ValinOnline com Phone 800 774 5630 Email CustomerService valin com ...

Страница 13: ...on Companies exceed the individual price of the Product on which liability is asserted Suitability of Use Omron Companies shall not be responsible for conformity with any standards codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product At Buyer s request Omron will provide applicable third party certification documents identifying rating...

Отзывы: