E5CN-H

Ordering Information

Controllers

Option Units

One of the following Option Units can be mounted to provide the E5CN with additional functions. 

Note:

These Option Units are applicable only to models released after January 2008.

Accessories (Order Separately)

USB-Serial Conversion Cable

Terminal Cover

Note: 1.

The Terminal Cover comes with the E5CN-

@@@

-500 

models.

2.

The E53-COV10 cannot be used. 

Waterproof Packing

Note:

Waterproof Packing is included with the controller only for 
models with terminal blocks.

Current Transformers (CTs)

Adapter

Note:

Use this Adapter when the panel has been previously prepared 
for the E5B

@

.

DIN Track Mounting Adapter

Front cover

CX-Thermo Support Software

Size

Case Color

Power supply voltage

Auxiliary output

Control output 1

Model

1/16 DIN 
48 

×

 48 

×

 78

(W 

×

 H 

×

 D)

Black

100 to 240 VAC

2

Relay output

E5CN-HR2M-500

Voltage output (for driving SSR)

E5CN-HQ2M-500

Current output

E5CN-HC2M-500

Linear voltage output

E5CN-HV2M-500

24 VAC/VDC

2

Relay output

E5CN-HR2MD-500

Voltage output (for driving SSR)

E5CN-HQ2MD-500

Current output

E5CN-HC2MD-500

Linear voltage output

E5CN-HV2MD-500

Silver

100 to 240 VAC

2

Relay output

E5CN-HR2M-W-500

Voltage output (for driving SSR)

E5CN-HQ2M-W-500

Current output

E5CN-HC2M-W-500

24 VAC/VDC

2

Relay output

E5CN-HR2MD-W-500

Voltage output (for driving SSR)

E5CN-HQ2MD-W-500

Current output

E5CN-HC2MD-W-500

Functions

Model

Communications
RS-485

3-phase heater burnout/SSR failure/
Heater overcurrent detection

E53-CNHH03N2

Heater burnout/SSR failure/
Heater overcurrent detection

Event inputs

E53-CNHBN2

Communications 
RS-485

Control output 2
(Voltage for driving SSR)

E53-CNQ03N2

Communications
RS-485

Heater burnout/SSR failure/
Heater overcurrent detection

E53-CNH03N2

Communications
RS-485

E53-CN03N2

Event inputs

E53-CNBN2

Heater burnout/SSR failure/
Heater overcurrent detection

Control output 2
(Voltage for driving SSR)

E53-CNQHN2

3-phase heater burnout/SSR failure/
Heater overcurrent detection

Control output 2
(Voltage for driving SSR)

E53-CNQHHN2

Event inputs

Control output 2
(Voltage for driving SSR)

E53-CNQBN2

Control output 2
(Voltage for driving SSR)

Transfer Output

E53-CNQFN2

Event inputs

Transfer Output

E53-CNBFN2

Communications
RS-232C

Control output 2
(Voltage for driving SSR)

E53-CNQ01N2

Communications
RS-232C

E53-CN01N2

Communications
RS-232C

Heater burnout/SSR failure/
Heater overcurrent detection

E53-CNH01N2

Model

E58-CIFQ1

Model

E53-COV17

Model

Y92S-P8

Hole diameter

Model

5.8 dia.

E54-CT1

12.0 dia.

E54-CT3

Connectable models

Model

Terminal type

Y92F-45

Model

Y92F-52

Type

Model

Hard Front Cover

Y92A-48B

Soft Front Cover

Y92A-48D

Model

EST2-2C-MV4

Buy Now: www.ValinOnline.com | Phone: 800-774-5630 | Email: [email protected]

Содержание E5CN-HC2M-500

Страница 1: ...or the most recent information on models that have been certified for safety standards refer to your OMRON website Universal Sensor Inputs Universal thermocouple Pt analog current voltage inputs Indication Accuracy Thermocouple Pt input 0 1 of PV Analog input 0 1 FS 2 level Display PV and SV 5 digit Display with high resolution of 0 01 C E5CN H Event Inputs None Two Sampling Period 60 ms Control O...

Страница 2: ...r overcurrent detection CT1 HH Heater burnout SSR failure Heater overcurrent detection CT2 B Two event inputs 03 RS 485 communications H03 Heater burnout SSR failure Heater overcurrent detection CT1 RS 485 communications HB Heater burnout SSR failure Heater overcurrent detection CT1 Two event inputs HH03 Heater burnout SSR failure Heater overcurrent detection CT2 RS 485 communications H01 Heater b...

Страница 3: ...elay output E5CN HR2MD W 500 Voltage output for driving SSR E5CN HQ2MD W 500 Current output E5CN HC2MD W 500 Functions Model Communications RS 485 3 phase heater burnout SSR failure Heater overcurrent detection E53 CNHH03N2 Heater burnout SSR failure Heater overcurrent detection Event inputs E53 CNHBN2 Communications RS 485 Control output 2 Voltage for driving SSR E53 CNQ03N2 Communications RS 485...

Страница 4: ...ow Approx 7 mA per contact Logic opera tions Number of operations 8 max Combinations can be made using work bits Operations Logic operation Any of the following four patterns can be selected The input status may be inverted A and B or C and D A or C and B or D A or B or C or D A and B and C and D A B C and D are four inputs Delay ON delay or OFF delay for the results of the logic operation given a...

Страница 5: ...0 500 0 500 0 400 0 400 0 400 0 400 0 400 0 200 00 200 00 200 00 200 00 100 0 100 0 100 0 0 0 0 0 0 0 0 0 0 0 0 0 50 00 20 0 50 00 100 0 20 0 50 00 50 00 100 0 200 0 199 9 199 9 200 0 200 0 199 9 200 0 200 0 199 9 200 0 Setting number 0 1 2 24 3 4 5 6 21 7 8 22 9 10 23 11 12 13 14 15 16 17 18 19 20 25 26 27 28 29 Shaded settings are the default settings The applicable standards for the input types...

Страница 6: ...n alarm value X is negative 0 Alarm function OFF Output OFF No alarm 1 1 Upper and lower limit 2 Set the deviation in the set point by setting the alarm upper limit H and alarm lower limit L 2 Upper limit Set the upward deviation in the set point by setting the alarm value X 3 Lower limit Set the downward deviation in the set point by setting the alarm value X 4 1 Upper and lower limit range 3 Set...

Страница 7: ...roportional band P Temperature input 0 1 to 3240 0 C or F in units of 0 1 C or F Analog input 0 1 to 999 9 FS in units of 0 1 FS Integral time I 0 0 to 3240 0 s in units of 0 1 s Derivative time D 0 0 to 3240 0 s in units of 0 1 s Control period 0 5 1 to 99 s in units of 1 s Manual reset value 0 0 to 100 0 in units of 0 1 Alarm setting range 19999 to 32400 decimal point position depends on input t...

Страница 8: ...ge 5 VDC Current consumption 70 mA Ambient operating temperature 0 to 55 C with no condensation or icing Ambient operating humidity 10 to 80 Storage temperature 20 to 60 C with no condensation or icing Storage humidity 10 to 80 Altitude 2 000 m max Weight Approx 100 g Transmission line connection method RS 485 Multipoint RS 232C Point to point Communications RS 485 two wire half duplex RS 232C Syn...

Страница 9: ... and Transfer Output 11 12 13 14 15 EV1 EV2 Event Inputs E53 CNBN2 E53 CNQHHN2 11 12 13 14 15 CT1 Control Output 2 and CT E53 CNQHN2 E53 CN03N2 E53 CNQ03N2 E53 CNH03N2 E53 CNHH03N2 E53 CNQFN2 E53 CN01N2 E53 CNH01N2 E53 CNQ01N2 E53 CNQBN2 E53 CNHBN2 E53 CNBFN2 SD RS 232C RD SG SD RD SG RS 232C 11 12 13 14 15 Communications RS 232 SD RD SG 11 12 13 14 15 11 12 13 14 15 RS 485 Communications RS 485 a...

Страница 10: ...ofing Panel Cutout Mounted Separately Group Mounted 48 48 44 8 44 8 48 8 6 1 5 91 78 58 Terminal Cover E53 COV17 Accessory Mounting Adapter Accessory Waterproof Packing Accessory E5CN H Recommended panel thickness is 1 to 5 mm Group mounting is not possible in the vertical direction Maintain the specified mounting space between Controllers To mount the Controller so that it is waterproof insert th...

Страница 11: ...n not be used E54 CT3 Accessory Armature 30 21 15 5 8 dia 25 3 40 10 5 2 8 7 5 10 Two 3 5 dia 40 40 30 12 dia 9 2 36 dia 15 30 Two M3 depth 4 Approx 3 dia 18 22 Approx 6 dia Plug Armature Lead E54 CT1 E54 CT3 Connection Example Plug E54 CT1 Thru current Io vs Output Voltage Eo Reference Values Maximum continuous heater current 50 A 50 60 Hz Number of windings 400 2 Winding resistance 18 2 Ω Thru c...

Страница 12: ...nted to E5CN H Note 1 Use this Adapter when the panel has already been prepared for the E5B 2 The Adapter is available only in black 50 61 3 5 38 48 100 5 Y92F 52 Note This Adapter cannot be used together with the Terminal Cover Remove the Terminal Cover to use the Adapter Mounted to E5CN H Buy Now www ValinOnline com Phone 800 774 5630 Email CustomerService valin com ...

Страница 13: ...on Companies exceed the individual price of the Product on which liability is asserted Suitability of Use Omron Companies shall not be responsible for conformity with any standards codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product At Buyer s request Omron will provide applicable third party certification documents identifying rating...