Section 5
Command Descriptions and Data Formats
●
Output Mode Setting
This command reads or writes the Output Mode of the Sensor Amplifier Unit that
corresponds to the specified unit number and output number.
If a measurement error occurs in hold mode, the previous value is retained.
●
Operating Mode
This command reads or writes the Operating Mode of the Sensor Amplifier Unit that
corresponds to the specified unit number and output number.
●
Detection
This command sets the Operating Mode of the Sensor Amplifier Unit that corresponds
to the specified unit number.
●
Timer Setting
This command sets the timer of the Sensor Amplifier Unit that corresponds to the
specified unit number and output number.
Bit
Description
Data
Output 1
Output 2
00 or 01
Output Mode
0: Normal detection mode
1: Area detection mode
2: Do not use.
3: Hold mode (SA0 only)
0: Normal detection mode
1: Alarm output mode (FA0/LA0)
2: Error output mode
02 to 31
No applicable data
Not used.
Not used.
Bit
Description
Data
00
Operating Mode
0: Light ON
1: Dark ON
01 to 31
No applicable data
Always 0
Bit
Description
Data
00
Detection Mode
0: SHS (Super-high-speed Mode), 1: HS (High-speed Mode),
2: STND (Standard Mode), 3: GIGA (High-resolution Mode)
01
02 to 31
No applicable data
Always 0
Bit
Description
Data
00 to 02
Timer Setting
0: Timer OFF
1: OFFD (OFF delay)
2: ON-D (ON delay)
3: SHOT (one-shot timer)
4: ONOFF (ON delay + OFF delay)
03 to 31
No applicable data
Always 0