47
E3NW-CRT
User’s Manual
Sect
ion 3
CompoN
et
Communic
a
tions
Spec
if
ic
at
ions
Section 3
CompoNet Remote I/O Communications
●
Command Data
Refer to Command Descriptions and Data Formats in Section 5 Appendices for details on
read, write, and execute command data.
●
Error Flags
The following table lists the error flags.
Light OFF
Both
---
---
0xC8
OK
OK
OK
Clear Light OFF
Both
---
---
0xDD
OK
OK
OK
Two-point Tuning First Point
Outputs 1 and 2 ---
---
0xC9
OK
OK
OK
Two-point Tuning Second Point
Outputs 1 and 2 ---
---
0xCA
OK
OK
OK
Position Tuning
Outputs 1 and 2 ---
---
0xCB
OK
OK
NA
Full Auto Tuning Setup
Outputs 1 and 2 ---
---
0xCC
OK
OK
OK
Execute Full Auto Tuning
Outputs 1 and 2 ---
---
0xCD
OK
OK
OK
Percentage Tuning Setting
Outputs 1 and 2 0x6E
0xCE
---
OK
OK
NA
Percentage Tuning Level
Outputs 1 and 2 0x6F
0xCF
---
OK
OK
NA
Execute Percentage Tuning
Outputs 1 and 2 ---
---
0xD0
OK
OK
NA
Power Tuning Setting
Both
0x71
0xD1
---
OK
OK
NA
Power Tuning Level
Both
0x72
0xD2
---
OK
OK
NA
Execute Power Tuning
Both
---
---
0xD3
OK
OK
NA
One-point Tuning
Outputs 1 and 2 ---
---
0xD4
NA
NA
OK
Flashing
Both
---
---
0xD7
OK
OK
OK
Clear Flashing
Both
---
---
0xDE
OK
OK
OK
Initialize
Both
---
---
0xD8
OK
OK
OK
Self-Trigger Level
Both
0x79
0xD9
---
NA
NA
OK
Tuning without a Workpiece
Outputs 1 and 2 ---
---
0xDA
NA
NA
OK
Background Suppression
Both
0x7B
0xDB
---
NA
NA
OK
Error Flag
Description
01
A command that cannot be processed by the Sensor Amplifier Unit was specified.
02
A command was executed when the Sensor Amplifier Unit could not respond.
04
The command data value is outside the Sensor Amplifier Unit’s allowable range.
08
A checksum error occurred.
10
The TRIGGER bit was turned OFF while execution of a command was in progress.
20
The command response timed out.
40
A command was sent to a disconnected Sensor Amplifier Unit
An incorrect Sensor output number was sent.
The command data value was outside the command’s allowable range.
Description
Output 1 and 2,
or Both
Read
Write
Execute
Applicable Sensor
Amplifier Units
FA0
LA0
SA0
OK: Supported,
NA: Not supported, ---: To communication unit