Output Control
Section 3-5
38
Counting Direction
For every Counter the (up or down) counting direction is indicated and can be
used in the Ladder Program.
3-5
Output Control
Output Control Mode
The 32 Outputs of the Counter Unit can be controlled automatically in two ways:
• Range Mode
In Range Mode you can define up to a maximum of 4 Ranges per Counter.
The Outputs are controlled according to the Counter Value being within
Range Limits. For a detailed description about Range Mode refer to section
• Comparison Mode
In Comparison Mode you can define up to a maximum of 8 Comparison
Values per Counter. The Outputs are controlled according to the direction in
which the Counter Value crosses the Comparison Value. For a detailed
description about Comparison Mode refer to section
.
If the Unit is configured for Range Mode all Counters will operate in Range Mode.
If the Unit is configured for Comparison Mode all Counters will operate in Compar-
ison Mode.
CNT3:
CNT4:
n+29
n+33
Gate Open/Closed:
0 = Gate Closed
1 = Gate Open
Counting Direction:
0 = Counter counts down
1 = Counter counts up
Preset Activated:
ON for exactly one PLC-cycle
Reset Activated:
ON for exactly one PLC-cycle
Capture Activated:
ON for exactly one PLC-cycle
Z-signal Activated:
ON for exactly one PLC-cycle
The Reset, Preset, Capture and Z-signal Activated Bits are ON for exactly one PLC-cycle after
the occurrence of a (short) pulse which was detected since the previous I/O Refresh.
CNT1:
CNT2:
n+21
n+25
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
General Setting:
m
Output Control Mode:
0 = Range Mode
1 = Comparison Mode
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
Содержание CJ1W-CTL41-E
Страница 2: ...i SYSMAC CJ series CJ1W CTL41 E 4 Channel Counter Unit Operation Manual Produced September 2004...
Страница 3: ...ii...
Страница 5: ...iv...
Страница 9: ...viii...
Страница 31: ......
Страница 43: ......
Страница 73: ......
Страница 119: ......
Страница 123: ......
Страница 126: ......
Страница 127: ......
Страница 131: ......
Страница 133: ...116...