![background image](http://html.mh-extra.com/html/omron/3g3mv-p10cdt-e/3g3mv-p10cdt-e_user-manual_743166026.webp)
Introduction
SECTION 1
13
Item
CPM2C-S 3G3MV-P10CDT
Method used to reference
the target value match
interrupt table
Comparison of all values in the
table, regardless of order of
appearance in table
Comparison of all values in the
table, regardless of order of
appearance in table
Reading range-comparison
results
Check AR 1100 to AR1107 or
execute PRV(62).
Check AR 1100 to AR1107 or
execute PRV(62).
High-speed
counter
(continued)
Reading status
Check AR 1108 (comparison in
progress), check AR1109
(high-speed counter PV
overflow/underflow), or execute
PRV(62).
Check AR 1108 (comparison in
progress), check AR1109
(high-speed counter PV
overflow/underflow), or execute
PRV(62).
Pulse synchronization
Supported. Supported.
Trapezoidal acceleration/
deceleration
Supported with ACC(––). The
initial frequency can be set.
Supported with ACC(––). The
initial frequency can be set.
PWM(––) output
Supported. Supported.
Number of simultaneous
pulse outputs
2 max.
2 max.
Maximum frequency
10 kHz max.
10 kHz max.
Minimum frequency
10 Hz
10 Hz
Pulse output quantity
–16,777,215 to 16,777,215
–16,777,215 to 16,777,215
Direction control
Supported. Supported.
Positioning to absolute
positions
Supported. Supported.
Bit status while pulses are
being output
No effect
No effect
Reading PV
Read SR 228 through SR231 or
execute PRV(62).
Read SR 228 through SR231 or
execute PRV(62).
Resetting PV
Supported. Supported.
Pulse output
control
Status outputs
Accelerating/decelerating
PV overflow/underflow
Pulse quantity set
Pulse output completed
Pulse output status
Accelerating/decelerating
PV overflow/underflow
Pulse quantity set
Pulse output completed
Pulse output status
Internal
Internal or none
Clock function
Words containing
time info.
AR 17 to AR 21
AR 17 to AR 21
Communications switch
This switch determines whether
communications are governed
by the standard settings or PLC
Setup settings. Also sets the
Programming Device
connection.
This switch determines whether
communications are governed
by the standard settings or PLC
Setup settings. Also sets the
Programming Device
connection.
Battery
Internal lithium battery backup
Unit with clock:
Internal lithium battery backup
Battery replacement
Possible
Not possible
Life expectancy/
backup time
2-year lifetime at 25
°
C
Unit with clock: 5-year lifetime
at
25
°
C
Battery
Battery error detection
Supported. Supported.
Содержание 3G3MV-P10CDT-E
Страница 2: ...3G3MV P10CDT PLC Option Unit User s Manual Revised June 2003 ...
Страница 38: ...Unit Components and Specifications SECTION 2 2 1 4 Dimensions 68 128 55 25 ...
Страница 43: ......
Страница 85: ...Example Programs Appendix B 72 ...
Страница 86: ...Example Programs Appendix B 73 ...
Страница 87: ...Example Programs Appendix B 74 ...
Страница 88: ...Example Programs Appendix B 75 ...
Страница 90: ...Example Programs Appendix B 77 ...
Страница 91: ...Example Programs Appendix B 78 ...
Страница 97: ...Example Programs Appendix B B 4 9 Programs User_Parameter_Init 84 ...
Страница 98: ...Example Programs Appendix B 85 ...
Страница 99: ...Example Programs Appendix B User_Application Pos_Loop 86 ...
Страница 100: ...Example Programs Appendix B 87 ...
Страница 101: ...Example Programs Appendix B 88 ...
Страница 102: ...Example Programs Appendix B 89 ...
Страница 103: ...Example Programs Appendix B 90 ...
Страница 104: ...Example Programs Appendix B 91 ...
Страница 105: ...Example Programs Appendix B 92 ...
Страница 106: ...Example Programs Appendix B 93 ...
Страница 107: ...Example Programs Appendix B Pos_Home_Sequence 94 ...
Страница 108: ...Example Programs Appendix B 95 ...
Страница 109: ...Example Programs Appendix B 96 ...