4-12
4-3 Pulse Train Position Control Mode
4
Func
tions
Speed Bias Function
This function applies speed command bias in the pulse train position control mode.
Set a bias value in frequency addition amount A145, and select a sign in frequency addition direc-
tion A146.
Allocate 50 (ADD) to any of the multi-function inputs. While the ADD terminal is turned ON, the bias
value is added to the speed command.
Orientation Function
This function determines a motor position at a single desired point during one rotation of the motor,
and can be used to exchange tools for a machine tool main spindle or others.
During positioning, the Z-pulse (one rotation position signal) is used as the reference signal. Input
Z-pulse between EZP and EZN.
Position command variation
Position feedback variation
P024
Position control
Speed feedback value
Speed control
A145
+/-
ADD terminal
Position bias
Speed bias
Set with A146.
Related
functions
A145, A146
Parameter No.
Function name
Data
Default setting
Unit
P011
Encoder pulses
128. to 9999./1000 to 6553
(10000 to 65530)
1024.
Pulse
P014
Orientation stop position
0. to 4095.
0.
−
P015
Orientation speed setting
0.00 to 99.99/100.0 to 120.0
5.00
Hz
P016
Orientation direction
setting
00: Forward side
00
01: Reverse side
P017
Position ready range
setting
0. to 9999./
1000 (10000)
5.
Pulse
P018
Position ready delay time
setting
0.00 to 9.99
0.00
s
P023
Position loop gain
0.00 to 99.99/100.0
0.50
rad/s
Содержание 3G3AX-PG
Страница 1: ...Cat No I564 E1 01 USER S MANUAL 3G3AX PG Encorder Feedback Board ...
Страница 2: ......
Страница 14: ...12 Contents ...
Страница 15: ...Chapter 1 Overview 1 1 Overview 1 1 ...
Страница 27: ...Chapter 3 Operation 3 1 Related Parameters 3 1 3 2 Precautions for Operation 3 8 ...
Страница 65: ...Chapter 6 Specifications 6 1 Product Specifications 6 1 ...
Страница 67: ......