3-6
3-1 Related Parameters
3
Opera
tion
Parameter
No.
Function name
Data range
Default setting
Changes dur-
ing operation
Unit
P057
Pulse train
frequency bias
amount
−
100. to +100.
0.
×
%
P058
Pulse train
frequency limit
0. to 100.
100.
×
%
P060
Multi-step position
command 0
Position range specification (reverse
side) to Position range specification
(forward side)
(Displays MSB 4 digits including “
−
”)
0
{
−
P061
Multi-step position
command 1
0
P062
Multi-step position
command 2
0
P063
Multi-step position
command 3
0
P064
Multi-step position
command 4
0
P065
Multi-step position
command 5
0
P066
Multi-step position
command 6
0
P067
Multi-step position
command 7
0
P068
Zero return mode
00: Low
01: Hi1
02: Hi2
00
{
−
P069
Zero return
direction selection
00: Forward side
01: Reverse side
00
{
−
P070
Low-speed zero
return frequency
0.00 to 10.00
0.00
{
Hz
P071
High-speed zero
return frequency
0.00 to 99.99
100.0 to Max. frequency
0.00
{
Hz
P072
Position range
specification
(forward side)
0 to 268435455 (at P012 = 02)
0 to 1073741823 (at P012 = 03)
(Displays MSB 4 digits)
268435455
{
−
P073
Position range
specification
(reverse side)
−
268435455 to 0 (at P012 = 02)
−
1073741823 to 0 (at P012 = 03)
(Displays MSB 4 digits)
−
268435455
{
−
Содержание 3G3AX-PG
Страница 1: ...Cat No I564 E1 01 USER S MANUAL 3G3AX PG Encorder Feedback Board ...
Страница 2: ......
Страница 14: ...12 Contents ...
Страница 15: ...Chapter 1 Overview 1 1 Overview 1 1 ...
Страница 27: ...Chapter 3 Operation 3 1 Related Parameters 3 1 3 2 Precautions for Operation 3 8 ...
Страница 65: ...Chapter 6 Specifications 6 1 Product Specifications 6 1 ...
Страница 67: ......