2-8
2-6 Switch Settings
2
Design
2-6 Switch Settings
Switch Arrangement
The switch arrangement is shown below.
Default Settings
The default settings (factory settings) are shown below.
*1 When connecting the multiple units in parallel for pulse train position command inputs, turn ON
the SWR1 and SWR2 of the only one unit located farthest from the master unit.
DIP switch
name
Switch No.
Settings
Default
setting
SWENC
1
ON
Disconnection detection enabled when encoder A
and B phases are not connected
OFF
OFF
Disconnection detection disabled when encoder A
and B phases are not connected
2
ON
Disconnection detection enabled when encoder Z
phase is not connected
OFF
OFF
Disconnection detection disabled when encoder Z
phase is not connected
SWR
*1
1
ON
Built-in termination resistor between SAP and
SAN (150
Ω
) enabled
OFF
OFF
Built-in termination resistor between SAP and
SAN disabled
2
ON
Built-in termination resistor between SBP and
SBN (150
Ω
) enabled
OFF
OFF
Built-in termination resistor between SBP and
SBN disabled
SWENC
SWR
1
2
TM1
TM2
Switch [ON/OFF] setting
Slide the switch from left (OFF) to
right to turn it ON.
O
F
F
Содержание 3G3AX-PG
Страница 1: ...Cat No I564 E1 01 USER S MANUAL 3G3AX PG Encorder Feedback Board ...
Страница 2: ......
Страница 14: ...12 Contents ...
Страница 15: ...Chapter 1 Overview 1 1 Overview 1 1 ...
Страница 27: ...Chapter 3 Operation 3 1 Related Parameters 3 1 3 2 Precautions for Operation 3 8 ...
Страница 65: ...Chapter 6 Specifications 6 1 Product Specifications 6 1 ...
Страница 67: ......